Replacing a Fixed Fan (Intel® Server Chassis SC5400Base SC5400BRP only)

Note: This procedure applies only to the Intel® Server Chassis SC5400 BASE and Intel® Server Chassis SC5400BRP configurations. The Intel® Server Chassis SC5400LX and SC5400LXi ship with hot-swap fans.

1.Observe the safety and ESD precautions at the beginning of this book.

2.Power down the server and unplug all peripheral devices and the AC power cable.

3.Remove the chassis cover. For instructions, see “Removing the Chassis Cover” on page 16.

4.Disconnect the appropriate fan power cable from the server board.

5.Remove the 92-mm (see letter “A” in the following figure) or 120-mm (see letter “B”) fixed fan from its snap-in bracket.

A

B

92-mm

120-mm

Fixed Fan

Fixed Fan

 

TP00991

Figure 14. Removing a Fixed Fan

6.Install new 92-mm or 120-mm fixed fan.

7.Connect fan power cable to the server board. See the Intel® server board Quick Start User’s Guide or User Guide for appropriate connection location.

8.Re-install the chassis cover. For instructions, see “Installing the Chassis Cover” on page 17.

9.Plug all peripheral devices and the AC power cable into the server and then power up the server.

Intel® Server Chassis SC5400 User’s Guide

23

Page 41
Image 41
Intel SC5400 manual Removing a Fixed Fan