Intel ZT 8101 10/100 BOOTP/DHCP Relay, To test connectivity with ping, Using the Telnet Console

Models: ZT 8101 10/100

1 140
Download 140 pages 23.33 Kb
Page 59
Image 59

Using the Telnet Console

3.In the Path\Filename field, enter the path on the TFTP server and the filename.

4.Highlight SAVE SETTINGS and press Enter. This saves the information so that the next time you access this screen, you won’t have to enter the address or the path\filename.

5.To start the file transfer to the TFTP server, highlight UPLOAD and press Enter.

To test connectivity with ping

1.From the Main Menu, select Switch Utilities Ping Test and press Enter.

2.Configure these fields.

Field

Description

 

 

IP Address

Specifies the IP address of the network device to ping.

 

 

Number of Repetitions

Specifies the number of test packets to send. Three is the usual number.

 

 

Default timeout

Specifies the number of seconds to wait between sending the packets.

 

 

3. To start the test, highlight START and press Enter.

BOOTP/DHCP Relay

BOOTP/DHCP relay agent enables end stations to use a BOOTP or DHCP server to obtain TCP/IP configuration information or boot files to be loaded into memory, even if the servers are not on the local IP interface. The following conditions determine whether you need to enable BOOTP/DHCP relay:

If the BOOTP or DCHP server and end station are on the same IP interface, no relay agent is necessary.

If the servers and the end stations are on different IP interfaces, a relay agent is necessary for the switch to forward the messages.

The relay agent forwards these packets between IP interfaces, and therefore must know the IP addresses of the BOOTP and DHCP servers and their respective subnet names (or IP interface names).

When the switch receives packets destined for a BOOTP or DHCP server, it forwards them to specific servers as defined in the following configuration. The switch also forwards packets from the BOOTP or DHCP servers to the appropriate subnets.

To enable the BOOTP/DHCP relay agent

1.From the Main Menu, select Switch Utilities BOOTP/DHCP Relay and press Enter.

Intel® NetStructure™ ZT 8101 10/100 Ethernet Switch User’s Manual

59

Page 59
Image 59
Intel ZT 8101 10/100 user manual BOOTP/DHCP Relay, To test connectivity with ping, To enable the BOOTP/DHCP relay agent