A p p e n d i c e s

C. Operating the LX T-04

The SYSTEM indicator

This indicator (green) is lit when the Intermate LX T-04 is connected to your IBM system. It can also flash under the following conditions:

Flash during a few seconds at power up.

￿Flash in Test Mode. Described later in this chapter.

Rapid flash during test function execution and during flash loading of new software.

Note: If the power up flashing continues, a hardware error has occurred. Contact your dealer/ distributor.

The Address Switch

The ten-position address switch is used to set the device address for the Intermate LX T-04. It is also used to set start conditions and to select and execute test functions during operation.

Start Conditions

The action when the Intermate LX T-04 is switched on is determined by the setting of the address switch, as follows:

Pos.

Description

0 - 6

Divice address in normal print operation.

7

Reserved.

8

Select IBM 4214 Printer emulation,

9

Perform a test printout.

 

 

I n t e r m a t e L X T - 0 4

57

Page 57
Image 57
Intermate manual Operating the LX T-04, Start Conditions