S o l v i n g P r o b l e m s

1.Make sure that your printer is on-line.

2.Set the address switch to '9', and wait for approx. 3 seconds until the SYSTEM indicator starts to flash. You are now in the Test Mode.

3.Set the address switch to '8' to start the printout.

4.Set the address switch to '9' when the printout is completed. The SYSTEM indicator stops flashing.

5.Select the device address to resume normal print operation.

Producing Hexdumps

A hexdump is a printout where the input data stream is printed as hexadecimal byte values rather than being interpreted as characters and control codes. The Intermate￿LX T-04 features two different types of hexdump modes

System hexdump

This mode traps the input SCS data before the character and control code conversion. The data is printed as EBCDIC

￿hexadecimal values. ASCII hexdump

The input data is converted to ASCII hexadecimal values before printing. This mode is useful if you want to see what printer control command a certain IBM control code corresponds to.

The procedure for producing a hexdumpis as follows:

1.Switch the printer and Intermate LX T-04 off and on.

2.Set the address switch to '9', and wait for approx. 3 seconds until the SYSTEM indicator starts to flash. You are now in the Test Mode.

I n t e r m a t e L X T - 0 4