15
Menu Configuration—SET-UP MENU

INFORMATION

Item To do Setting value
STATUS DISPLAY Set if you want the information of the current input to
be displayed on the screen (see “Displaying the current
status” on page 11).
AUTO, OFF
SUB HOUR METER Display the hours of current use (unit: hour). You can reset only this item by pressing
3.
reset Restore the default setting for “STATUS DISPLAY” and “SUB HOUR METER.”
MODEL Display the model name and version of the monitor. This item is used for
maintenance of the monitor.
VERSION
HOUR METER Display the total hours of use (unit: hour). This item is used for maintenance of the
monitor. This item cannot be reset.

SECURITY LOCK

Item To do Setting value
SECURITY LOCK Activate/deactivate the Security Lock. ON, OFF
PASS ID SETTING Set the password for the Security Lock. 4 numbers
• For details about the Security Lock, see page 17.

COLOR TEMP.

Item To do Setting value
COLOR TEMP. Display the color temperature.
R DRIVE, G DRIVE,
B DRIVE
Adjust the drive level of each color (red, green, and blue). MIN += 000 += MAX
(in 256 grades)
R CUT OFF, G CUT
OFF, B CUT OFF
Adjust the cut-off point of each color (red, green, and
blue).
MIN += 000 += MAX
(in 256 grades)
reset Restore the default setting for all the items in “COLOR TEMP.”
• Adjust the color temperature after selecting color temperature (HIGH, MID, LOW, or USER) on the main
menu (see “PICTURE SETTING” on page 13).

SYNC FUNCTION

Item To do Setting value
NO SYNC ACTION Select the screen color or the screen status applied when
no signal is coming in.
OFF, GRAY BACK (gray
screen), POWER SAVE
(power save), RED,
GREEN, BLUE
DELAY TIME Set the time to change the screen color/screen status
set in “NO SYNC ACTION” above after signal-incoming
stopped.
30sec., 5min., 15min.
reset Restore the default setting for all the items in “SYNC FUNCTION.”
• While the Dual Display is activated, the Sync Function works only for the main window.

REMOTE SYSTEM

Item To do Setting value
ID Assign the ID to the monitor. 01 += 25
REMOTE IN SEL. Select the input terminal used for external control. D-sub9 (RS-232C input),
RJ-45 (RS-485 input/
output), LAN (Ethernet
terminal)
CNT. RJ45 OUT Select the external control method for RS-485 OUT
terminal.
RS485, IR OUT
CNT. RJ45 IN Select the external control method for RS-485 IN terminal. RS485, MAKE, TRIG.,
SET
PORT F1 – PORT
F5
Assign the control function to the RS-485 IN terminal’s
pins (1 to 5) when selecting “SET” in “CNT. RJ45 IN”
above.
– – – (no function),
VIDEO, RGB, DVI,
POWER, ASPECT,
MUTING, PIP, PBP
reset Restore the default setting for all the items in “REMOTE SYSTEM.”
• For details about external control, see pages 20 to 25.