How to Use External Control

20

 

 

About the external control

This monitor has the following external control terminals:

RS-232C terminal: Controls the monitor by external control equipment (a personal computer or a dedicated controller) (see “Using the serial communication” on page 21).

RS-485 terminals: The following external control systems are available.

(1)Serial communication: Controls the monitor by external control equipment (a personal computer or a dedicated controller) (see page 21).

(2)IR OUT system: Controls other equipment through the monitor by using the remote control supplied with the equipment.

(3)MAKE (make contact system): Controls the function by short-circuiting the corresponding pin terminal to the GND pin terminal, or disconnecting (opening) it (see page 22).

(4)TRIG. (trigger system): Controls the function by inputting the pulse signal instantaneously to the corresponding pin terminal (see page 22).

LAN terminal (10BASE-T):Controls the monitor from a PC in the network through the web browser (see “Using the LAN system” on page 23).

Set the following items in “REMOTE SYSTEM” according to the external control terminal and control system you use (see page 15).

Control system

 

“REMOTE IN SEL.”

“CNT. RJ45 OUT”

“CNT. RJ45 IN” setting

 

setting

setting

 

 

 

Serial

RS-485

RJ-45*1

RS485

RS485

communication

RS-232C

D-sub9*1

RS485

RS485

IR OUT system

 

Any

IR OUT

Any

MAKE system

 

RJ-45

RS485

MAKE

TRIG. system

 

RJ-45

RS485

TRIG.

LAN system*2

 

LAN

Any

Any

<IR OUT system>

Control signals from the remote control of external equipment are sent out to the equipment through the RS- 485 OUT terminal. Consult your dealer for details.

• You cannot use the IR OUT system and the serial communication via the RS-485 terminal at the same time.

Karaoke component, etc.

RS-485

OUT

Remote control

<MAKE/TRIG. system>

You can control the monitor by external control equipment*3. See also page 22.

*3 External control equipment is not commercially available. Consult your dealer if you need a dedicated controller.

<LAN system>

You can control the monitor from PC in your Local Area Network (LAN) through the web browser.

*1 For the monitor connected to the external control equipment, set “REMOTE IN SEL.” according to the actual connection. Set other monitors to “RJ-45.”

*2 Set “NETWORK SETTING” in the set-up menu (see pages 16 and 23).

NOTE

The functions controlled by an external device through the MAKE connection cannot be controlled on the main unit or the remote control.

While the Control Lock (see page 16) is in use, you can use external control.

<Serial communication>

Several monitors can be controlled by connecting their RS-485 IN and OUT terminals. See also page 21. Do not use the AC OUT terminal on the monitor for power supply to another monitor.

External control equipment

RS-485 IN

RS-485

RS-485

RS-485

RS-485

RS-485

or RS-232C

OUT

IN

OUT

IN

OUT

LAN

Hub

Hub

PC

PC

Monitor

PC

Page 20
Image 20
JVC GM-F420S, GM-F520S, GM-F470S specifications About the external control, Remote in SEL CNT. RJ45 OUT