How to Use External Control (cont.)

22

 

 

Using the MAKE/TRIG. system

The RS-485 IN terminal is configured as follows. You can assign the functions to each pin terminal by setting “REMOTE SYSTEM” (see “PORT F1 – PORT F5” on page 15).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin No.

Pin name

 

Pin No.

Pin name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

PORT F1

 

5

PORT F5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

PORT F2

 

6

ENABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

PORT F3

 

7

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a female terminal.

4

PORT F4

 

8

GND

To assign the functions to the pin terminals

For the operation procedure, see page 12.

1.Select “REMOTE SYSTEM” on the set-up menu.

2.Set “CNT. RJ45 IN” to “SET.”

3.Select a pin name (“PORT F1” – “PORT F5”) which you want to assign a function, and then select the function you want to assign.

• For functions which can be assigned, see the table below.

Functions controlled by MAKE/TRIG. system

Display

Functions to be controlled

Opening

Short-circuiting

 

 

 

 

VIDEO

Changes the input to VIDEO.

Invalid

Valid

 

 

 

 

RGB

Changes the input to RGB.

Invalid

Valid

 

 

 

 

DVI

Changes the input to DVI.

Invalid

Valid

 

 

 

 

POWER

Turns on/off the monitor.

Power on

Power off (standby)

 

 

 

 

ASPECT

Changes the aspect ratio.

REGULAR

FULL

 

 

 

 

MUTING

Turns off or resumes the volume.

Muting off

Muting on

 

 

 

 

PIP

Turns on/off the PIP mode (see page 11).

Invalid

Valid

 

 

 

 

PBP

Turns on/off the PBP mode (see page 11).

Invalid

Valid

 

 

 

 

– – –

No function

 

 

 

 

NOTE

You cannot assign the same function to different pin terminals.

The TRIG. (trigger) system switches each function by short-circuiting for approx. 1 second.

Operation

1.Short-circuit the 6th pin terminal (External control) to the 8th pin terminal (GND) so that the monitor can be controlled by the external control.

2.Set “CNT. RJ45 IN” of “REMOTE SYSTEM” to “MAKE” or “TRIG.” on the set-up menu.

3.When selecting “MAKE” (make contact) system:

Operate each function by short-circuiting the corresponding pin terminal to the 8th pin terminal (GND) or opening it.

When selecting “TRIG.” (trigger) system:

Operate each function by Pulse control, that is short-circuiting the corresponding pin terminal to the 8th pin terminal (GND) for about 1 second.

NOTE

When changing input, only one terminal must be short-circuited. (Other terminals must be opened.)

When switching PIP and PBP modes, open the mode which has been short-circuited before short-circuiting the mode you want to make valid.

When selecting the “TRIG.” (trigger) system, you can operate only one function at a time. Operate the functions one by one.