11. MENU SCREENS

11-12 HEADER REC Menu Screen

The HEADER REC menu screen is used for settings related to the HEADER REC function. (page 56)

Item

 

Function

Variation Range

Initial Setting

START KEY

Sets whether the HEADER REC operation should be executed when

STOP+VTR

DISABLE

 

the VTR trigger button is pressed while the STOP button is pressed.

DISABLE

 

 

STOP+VTR : HEADER REC operation is executed.

 

 

 

DISABLE

: HEADER REC operation is not executed.

 

 

 

 

 

 

TC DATA

Sets the time code value for the point when the Record-Standby mode

EXECUTE

EXECUTE

 

is engaged following completion of HEADER REC.

CANCEL

 

 

EXECUTE : Confirms the set time code.

 

 

 

CANCEL

: Clears the set time code.

 

 

*The time code value at the point when the Record-Standby mode is engaged may differ some frames from the value set for this item.

TC CLEAR

To reset the time code setting of the TC DATA item, set to EXECUTE

EXECUTE

CANCEL

 

and then press the SHUTTER dial.

CANCEL

 

 

EXECUTE : Resets.

 

 

 

CANCEL : No reset.

 

 

 

 

 

 

 

 

UB DATA

Sets the user’s bits of the HEADER REC section.

EXECUTE

EXECUTE

 

EXECUTE : Confirms the set user’s bits.

CANCEL

 

 

CANCEL : Clears the set user’s bits.

 

 

 

 

 

 

 

 

 

 

MEMO:

 

 

 

The user’s bits for the normal recording section are set on the TC/

 

 

 

 

UB/CLOCK menu screen.

 

 

 

When the network pack KA-DV5000 is connected, and the HEADER

 

 

 

 

REC section should be recorded on the CF card, make sure to set

 

 

 

 

the user’s bits for the HEADER REC section and the normal

 

 

 

 

recording section to the same value.

 

 

 

This item cannot be set when the UB REC item on the TC/UB/

 

 

 

 

CLOCK menu screen is set to OFF. In this case, “- - - -” is displayed.

 

 

 

 

 

 

 

 

UB CLEAR

To reset the user’s bits setting of the UB DATA item, set to EXECUTE

EXECUTE

CANCEL

 

and then press the SHUTTER dial.

CANCEL

 

 

EXECUTE : Resets.

 

 

 

CANCEL : No reset.

 

 

 

 

 

 

 

 

BARS TIME

Sets the duration (seconds) in which the color bar signal and test tone

0 SEC

30 SEC

 

(1 kHz) is recorded during HEADER REC. (1-sec steps)

~

 

 

 

 

 

 

 

 

 

 

99 SEC

 

 

 

 

 

BLACK TIME

Sets the duration (seconds) in which the black signal is recorded during

0 SEC

30 SEC

 

HEADER REC. (1-sec steps)

~

 

 

 

 

 

 

 

 

 

 

99 SEC

 

 

 

 

 

PAGE BACK

The TC/UB/CLOCK menu screen returns when the SHUTTER dial is

–––––

–––––

 

pressed.

 

 

E-78

Page 78
Image 78
JVC GY-DV5000 manual Header REC Menu Screen