1. INTRODUCTION

1-2 Routine and Periodical Maintenance

The GY-DV5000 incorporates precision mechanical parts, which will collect dirt, wear out and deteriorate as the unit is used. After the unit has been used for a long period even in a normal environment, the heads, drums and tape transport mechanisms also collect dirt. Especially, dust which penetrates the inside of the VCR section during outdoor use will promote the wear and deterioration of mechanical parts by causing poor contact between tape and heads or failing to maintain the video and audio quality at high levels. To prevent wear and deterioration, clean the mechanical parts using a head cleaning tape as routine maintenance. However, cleaning with a head cleaning tape alone is not enough for cleaning the entire tape transport mechanism, so it is also recommended to apply periodical maintenance (inspection) to prevent the sudden occurrence of failure. As the replacement, adjustment and servicing of parts require advanced skill and equipment, please consult the person in charge of professional video equipment at your nearest JVC-authorized service agent.

Head Cleaning

To maintain beautiful pictures and sound, be sure to use a head cleaning tape to clean the head periodically. (Read the “Precautions for Use of Head Cleaning Tape”.) If head cleaning is not performed periodically, a type of mosaic noise called block noise may appear in the picture or sound may be interrupted.

Block Noise

Please use cleaning tape produced by JVC. Do not use head cleaning tapes other than specified. Read the precautions and instructions for use of the head cleaning tape.

When dust adheres to the heads, the warning message “HEAD CLEANING REQUIRED!” is displayed on the LCD monitor and in the viewfinder during playback, edit search, and recording check using the RET button on the lens section.

Periodical Maintenance

Contents : Check or replace the following mechanical parts according to the running time.

Running Time

500H

1000 H

1500H

2000H

4000H

 

 

 

 

 

 

Drum ass’y (including heads)











Head cleaner











Tape guides & rollers











Reel disc and tension bands







: Check

: Clean, check and adjust.

: Clean and check. Replace as required.

: Replace.

The maintenance contents vary depending on the operating environment and method. Therefore, the above data should be considered as a reference.

Time management

The accumulated running time of the unit can be confirmed with the hour meter display (which shows the accumulated drum running time). For details, see “HOUR METER DISPLAY” on page 94.

For consultations related to the maintenance planning or cost, please contact the person in charge of professional video equipment at your nearest JVC-authorized service agent.

1-3 Precautions for Use of Head Cleaning Tape

Please use cleaning tape produced by JVC.

Adhere to the following precautions when using the head cleaning tape.

1. Insert the cleaning tape. Press the PLAY button after the cleaning tape is fully loaded. The tape runs for 10 seconds at a time in the PLAY mode. (The tape stops automatically and then the unit enters the STOP MODE.)

2. Do not use the tape more than four times at the most for each cleaning.

Use the following chart as a guide for periodical head cleaning.

Note 1) When used in a low humidity environment, head cleaning should be conducted at intervals half of those given in the below chart.

Note 2) If an ME80 tape is used immediately after head cleaning, the “HEAD CLEANING REQUIRED!” indicator may remain on. In this case, let the tape run as the indicator will turn off after the tape has run for a while.

Note 3) Use the cleaning tape in the room temperature (10˚C to 35˚C).

Note 4) The cleaning tape case contains instructions for use of the cleaning tape. However, some of these instructions differ from the contents of this sheet. When using the cleaning tape, please follow the instructions of this sheet.

Note 5) If the “HEAD CLEANING REQUIRED!” does not disappear after repeated head cleanings, the recording tape may be abnormal. Avoid excessive repeated use of the head cleaning tape.

Operating

Low temperature

Room temperature

High temperature

environment

0˚C to 10˚C

10˚C to 35˚C

35˚C to 40˚C

 

 

 

 

Yardstick for use

1 to 2 times

1 to 2 times

1 to 2 times

of cleaning tape

every 5 hours

every 20 to 30 hours

every 5 hours

E-7

Page 7
Image 7
JVC GY-DV5000 manual Routine and Periodical Maintenance, Precautions for Use of Head Cleaning Tape, Time management