4. POWER SUPPLY

4-2 Battery Pack Operation (Optional) (Cont’d)

REMAINING BATTERY POWER DISPLAY

OPEN

 

 

LCD

BRIGHT

DISPLAY

 

AUDIO

 

 

PULL

 

LEVEL

FRONT

OPEN

CH-1

CH-2

REAR

 

CH-1

CH-2

 

 

 

AUDIO INPUT

 

 

 

AUDIO SELECT

 

 

 

CH-1

CH-2

 

 

 

 

AUTO

 

 

 

MANUAL

 

LCD monitor

LOW VOLTAGE

10.5V

To display the remaining battery power accurately, set the BATTERY TYPE item on the OTHERS (2/2) menu screen in accordance with the type of the battery pack in use.

See “BATTERY TYPE” on page 81.

When the remaining battery power is nearly exhausted, the following warnings will be generated.

Viewfinder screen or LCD monitor

When a Status screen is displayed (excluding the Status 2

screen in the Camera mode)

Alarm indication: LOW VOLTAGE displayed.

Viewfinder lamps

TALLY lamp

Viewfinder

LOW VOLTAGE

BATT lamp and TALLY lamp: Blinks

BACK TALLY lamp on camera: Blinks

Monitoring loudspeaker and PHONES jack: Alarm sound

After the remaining battery power warnings appear, the

GY-DV5000 automatically stops operation if the battery

power operation is continued.

10.5V

Battery lamp

REC

BATT ALARM

Operating Time with Battery Pack

When the VF-P115B is used as the viewfinder and a fully charged battery pack is attached, the approximate continuous operating time is as follows:

Battery Pack

Continuous Operating Time (at 25 ˚C)

 

 

NP-1B

60 minutes

(SONY)

 

Magnum 14

130 minutes

(Anton-Bauer)

 

NP-L50

100 minutes

(NP-1B Type)

 

(IDX)

 

 

 

Battery operating time may differ depending on the age of the battery, charging conditions and the operating environment, etc. Use the values in the table on the left for approximate reference times.

Operating time is reduced in areas with a cold environment.

Operating time is reduced when the power zoom lens and LCD are used frequently.

PRECAUTIONS FOR THE BATTERY PACK

When the battery pack is not in use, it must be stored in a cool, dry place.

Do not leave the battery pack in a place where it might be subject to a high temperature (under direct sunlight in a car, etc.), this could cause leakage of the fluid or shorten service life.

When the terminal section of the battery pack gets dirty, the operating time will be shortened.

If the operating time becomes greatly reduced even immediately after recharging, the service life of the battery pack is nearly finished. Purchase a new battery pack.

Recharging

Recharge the battery pack after completely discharging it. Repeated recharging with residual charge remaining could result in reduced battery capacity.

If the battery capacity is reduced by repeating incomplete recharging, or recharging without discharging, once discharge the battery pack completely, then recharge it to restore the battery capacity.

If the battery pack is recharged with its internal temperature raised immediately after use, recharging may not be performed completely.

E-36