Settings (Step 2 Network Settings)
Alarm Input
| Item |
| Function/Set Value | Initial Value |
1 Alarm 1/Alarm 2 | This section describes setting procedures for alarm input. | — | ||
| Mode | For selecting whether to enable or disable the input signals. | Not Available | |
|
| Set Values : Available, Not Available |
| |
| Detect Mode | For selecting the method for detecting input signals. | Make | |
|
| Make : Detect input signals at the "Make" contact point. |
| |
|
| Break : Detect input signals during "Break". |
| |
|
| Toggle : Detect input signals at both "Make" and "Break". |
| |
| Alarm Output | For selecting whether to output from the alarm output terminal | Not Available | |
|
| when there is alarm input. |
| |
|
| Not Available : Do not output from the alarm output terminal. |
| |
|
| Alarm Output 1 : Send output from the Alarm Output 1 terminal. |
| |
|
| Alarm Output 2 : Send output from the Alarm Output 2 terminal. |
| |
|
| Note |
|
|
|
| • Unless the alarm output in the "Alarm Output" tab is enabled, |
| |
|
| this function will not be activated even if alarm output is |
| |
|
| selected in the alarm input settings. (☞ Page 44) |
| |
|
|
|
| |
| Message Packet | For setting whether to send alarm packets to the PC when there | Not Available | |
|
| is alarm input. |
|
|
|
| Not Available : Do not send alarm packets. |
| |
|
| Available | : Send alarm packets. |
|
| Alarm FTP | For operation according to the [Alarm FTP] in the FTP Client | Not Available | |
|
| feature when there is alarm input. Please refer to FTP Client |
| |
|
| Settings (☞ Page 50) for details on alarm FTP. |
| |
|
| Set Values: Available, Not Available |
| |
| Shutdown | Set to "Available" to quit all operations upon alarm input. Using | Not Available | |
|
| this Shutdown function enables operations of this camera to |
| |
|
| end safely even during recording into CF cards. |
| |
|
| Not Available : Do not shut down. |
| |
|
| Available | : Shut down. |
|
Note
•When this is set to "Available", all alarm input except alarm output and message packets will be disabled.
Item | Function/Set Value | Initial Value |
2 Relay Alarm | Set here to enable the relay alarm function, which is activated | Not Available |
| when 2 alarms are received within a preset time interval. |
|
| The sequence and time interval for the alarm input can be specified. |
|
| When [Alarm Output] is selected, alarm signal output will be |
|
| sent to the alarm output terminal on the ceiling mount accord- |
|
| ing to the output port settings. |
|
Notes
•A second alarm input enables this relay alarm function, and alarm will not be activated for this second input.
•Unless the alarm output in the "Alarm Output" tab is
enabled, this function will not be activated even if alarm output is selected in the alarm input settings. (☞ Page 44)
•Alarm Output * Please refer to the [Alarm 1/2] item for details on the set val- *Please
• Message Packet | ues. | refer to |
• Alarm FTP |
| the [Alarm |
• Shutdown |
| 1/2] item |
|
| for the |
|
| initial |
|
| values. |
|
|
|
3 Retry (1 to 3) | For setting the no. of times alarm notification is to be sent to | 1 |
| the "V.Networks Controller". (Set Value: 1 to 3) |
|
| Note |
|
| • Alarm notification may fail, depending on the LAN |
|
| environment in use. If it fails, set the value for alarm |
|
| notification to "3". In this case, alarm by the "V.Networks |
|
| Controller" itself is set off only once. |
|
|
|
|
4 List | Press here to display the IP address of the PCs to which an | — |
| alarm notification is sent. ("Distribution Address List" Screen) |
|
| To delete a distribution address, select the IP address to de- |
|
| lete, followed by pressing the Delete button. |
|
Notes
•The list allows setting of up to 10 addresses.
•Message packets will not be sent out when there are 11 or more addresses.
42 |
|
|
| 43 |