Settings (Step 2 Network Settings)

2-4 Other Settings Using the "VN-C205U Setup Tool" (4. Alarm Setting) (Continued)

 Other Triggers

 

Item

 

Function/Set Value

Initial Value

 

 

 

5 Motion Detection

For setting alarm operations when motion is detected within

 

 

the area specified in the motion detection settings.

 

 

• Mode

* Please refer to the [Alarm 1/2] item for details on the set val-

*Please

 

• Alarm Output

ues.

 

refer to

 

Message Packet

 

 

the [Alarm

 

• Alarm FTP

 

 

1/2] item

 

 

 

 

for the

 

 

 

 

initial

 

 

 

 

values.

 

 

 

 

 

 Alarm Output

 

 

 

 

Item

 

Function/Set Value

Initial Value

6 Output 1/

This section describes the setting procedures for alarm output.

OFF

 

Output 2

Set Values

: ON, OFF

 

 

Output Value

Select the alarm output method.

 

 

Output OFF : Output alarm signals when the Alarm Output 1

 

 

 

 

or Alarm Output 2 terminal is connected to the

 

 

 

 

GND terminal.

 

 

 

Output ON : Output alarm signals when the Alarm Output 1

 

 

 

 

or Alarm Output 2 terminal and the GND terminal

 

 

 

 

are disconnected from each other.

 

 

Pattern

Level

: Continue output of alarm signals throughout the

 

 

 

alarm input process.

 

 

 

Momentum : Output alarm signals only at the specified time.

 

 

 

 

Specify time using the Return Interval item.

 

 

 

 

 

 

Interval

For setting the output interval when the Output Pattern item is

 

 

set to Momentum.

 

 

 

This is disabled when the Output Pattern item is set to Level.

 

 

 

 

 

7 Output 1

Upon pressing the Output button, alarm signal output will be

 

force output/

sent from the alarm output terminal on the ceiling mount.

 

 

Output 2

This is used for checking the alarm operation.

 

 

force output

Note

 

 

 

 

 

 

Output is disabled when the Output Pattern item is set to "Level".

2-4 Other Settings Using the "VN-C205U Setup Tool" (5. Recording Setting)

This function is used to perform settings for local recording, which records camera images to the CF card when the alarm is activated. Please purchase the CF card separately. (Page 19)

When an alarm is activated, recording can be performed via "local recording", where camera

images are saved into a CF card, or via the V.Networks Controller, where these are saved into the hard disk of the PC. (Page 67)

1.Start up the "VN-C205U Setup Tool" and select [Recording]. To make new values effective, click on [Apply], followed by [OK].

Setting the [Trigger Recording] screen

1 Select alarm input signal “Trigger” for starting local recording.

44

 

 

 

45

Page 23
Image 23