B FTP (continued)

Time Filter

: For specifying the periodic FTP transfer action with respect to each

 

 

 

day of the week and setting the corresponding time of the day.

 

 

Applicable day of week

 

 

 

: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday,

 

 

 

Saturday

 

 

Alarm action

: Mask span

 

 

 

Unmask span

 

 

 

Mask All

 

 

 

Unmask All

 

 

Applicable time period

 

 

 

: For specifying the Start and End time in hours and minutes.

 

 

Pre-/Post-recording parameter:

 

 

[PrePostRecording Frame Rate]

 

 

 

: For specifying the JPEG frame rate for FTP pre-/post-

 

 

 

recording.

 

 

 

[Setting values : 1 fps, 2 fps, 3 fps, 5 fps, 6 fps, 7.5 fps,

 

 

 

10 fps, 15 fps, 30 fps]

 

 

[PrePostRecording Before Trigger]

 

 

 

: For setting the FTP pre-recording trigger time (recording

 

 

 

time before alarm input) in seconds.

 

 

 

[Setting values : 0sec to 60sec]

 

 

[PrePostRecording After Trigger]

 

 

 

: For setting the FTP post-recording trigger time (recording

 

 

 

time after alarm input) in seconds.

 

 

 

[Setting values : 0sec to 60sec]

 

 

The maximum time intervals for [PrePostRecording Before Trigger] and

 

 

[PrePostRecording After Trigger] are determined by the JPEG size on the

 

 

Encoding page as well as [PrePostRecording Frame Rate]. A message

 

 

appears if the combination of the entered values are not feasible.

 

 

C Alarm Output

For setting the alarm output.

 

 

 

 

Duration

For setting the output time of [Manual Output].

 

 

[Setting range : 0 / 100msec to 5000msec]

 

 

 

 

Manual Output

For operating alarm output manually.

 

 

The current output status appears on the right. When [Duration] is set to A0B,

 

 

pressing the [Make] button switches the alarm to Make output, while

 

 

pressing the [Break] button switches the alarm to Break output.

 

 

When [Duration] is set to a value other than A0B, pressing the [Make] button

 

 

switches the alarm to Make output only during the duration of the output,

 

 

upon which it switches to Break output.

 

 

When the output duration is set to a value other than A0B, pressing the

 

 

[Break] button switches the alarm to Break output only during the duration of

 

 

the output, upon which it switches to Make output.

 

 

 

 

53