Problem

Probable Cause

Corrective Action

Page

Ref.

 

 

 

 

 

 

 

The way the transceiver

The electrical contacts on the front

Clean the electrical contacts on both the front

functions or displays

panel and main unit were soiled.

panel and the main unit using a clean damp

 

information is strange.

 

cloth.

 

 

 

 

 

The display is too dim,

The supply voltage is too low.

The supply voltage requirement is

3, 4

even though you selected

 

13.8 V DC ± 15% (11.7 V to 15.8 V DC).

 

a high dimmer level.

 

If the input voltage is outside this range,

 

 

 

recharge your battery, adjust your regulated

 

 

 

power supply, and/or check all power cable

 

 

 

connections.

 

 

 

 

 

The frequency cannot be

Memory Recall or the Call channel

Press [VFO].

8

selected by turning the

was selected.

 

 

Tuning control or by

 

 

 

pressing Mic [UP]/[DWN].

 

 

 

 

 

 

 

Most buttons/keys and the

1 One of the Lock functions is ON.

1 Unlock all of the Lock functions.

67

Tuning control do not

2 The front panel was not

2 Separate the front panel from the main unit

84

function.

connected securely to the main

by using the release switch on the rear of

 

 

 

 

unit of the transceiver.

the front panel, then lock the front panel

 

 

 

securely to the main unit by using the same

 

 

 

switch.

 

 

 

 

 

Memory channels cannot

1 No data has been stored in any

1 Store data in some memory channels.

30

be selected by turning the

memory channels, or stored data

 

 

Tuning control or by

was erased by Full Reset.

 

 

pressing Mic [UP]/[DWN]

2 The Call channel was selected.

2 Press [MR] to switch to Memory Recall.

31

when using Memory

 

 

 

Recall.

 

 

 

 

 

 

 

 

 

Continued