26)Inert the adjustment nipple into the main tube on the end opposite end from the adjustment knob. Using a flat blade screwdriver, thread the nipple into the tube slowly.

As soon as you see any movement of the lever stop screwing the nipple in. Turn in on the flex knob until an audible click is heard.

27)It is recommended that the regulator sit for 24 hours before any further assembly is completed. This will allow the seat to conform itself correctly to the inlet nipple.

28)Bend the lever down and carefully install this assembly of the main tube and adjustment knob into the regulator until the threaded end of this assembly comes completely through the opposite side of the regulator body.

29)Install the o-ring and the bent tube adapter and tighten to 30 inch pounds.

30)Tighten the packing nut at the flex knob with a one inch wrench to 30 inch pounds.

31)Install the lock clip on the main tube.

32)Adjust the regulator per this chapter.

33)Reinstall the diaphragm, cover and cover retain- ing ring.

34)Reinstall the bent tube assembly as per this chapter.

35)Once the regulator is properly adjusted, reinstall the washers and screws that secure the regulator cover and ring. Tighten the screws to 12 inch pounds.

Install the o-ring in the bent tube adapter.