Kirby appendix Kirby Morgan 37 SuperFlow 450 Regulator Removal, 109

Models: 37

1 50
Download 50 pages 33.99 Kb
Page 42
Image 42

Kirby Morgan 37 & 57

7.12.4SuperFlow 450 Regulator Removal

Required Tools:

11/16 inch Open-end Attachment on Torque Wrench

7/8 inch Open-end Wrench, Torque Wrench and 1 3/8 inch Socket

1 /4 inch Flat Blade Attachment on Torque Screw- driver

1)Remove the bent tube assembly, per this chapter.

2)Remove the screws, kidney plates and whisker spacers from the whiskers.

Be sure to remove and set aside the whisker spacers.

3)Remove the nose block device per chapter 8.

4)Remove the oral nasal mask per this chapter.

5)The regulator mount nut is removed along with the sealing O-ring.

6)Cut the tie wrap that connects the regulator body to the Quad Valve cover.

7)Now the regulator assembly can be pulled out of the helmet.

8)The center section of the exhaust whisker, named the exhaust main body has a tie wrap holding it in place. Remove the tie wrap then stretch the body off the regulator exhaust flange.

Remove the regulator from the helmet.

Separate the regulator from the Quad valve exhaust whiskers.

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001