Kirby 37 appendix 117

Models: 37

1 50
Download 50 pages 33.99 Kb
Page 50
Image 50

Kirby Morgan 37 & 57

3)Install the sealing o-ring and regulator mount nut. Do not tighten the nut at this time.

4)Tighten the screws that connect the exhaust main body to the quad exhaust cover.

5)Install the oral nasal mask per this chapter.

6)Install the nose block device per chapter 8.

7)Install the bent tube assembly, per this chapter.

8)Tighten the regulator mount nut to 75 inch pounds.

9)Install the screws, kidney plates and whisker spac- ers from the whiskers. Tighten the screws to 12 inch pounds.

Tighten the screws that connect the quad exhaust cover to the exhaust body.

Connect the bent tube assembly and tighten at both ends.

Tighten the screws that fasten the whiskers to the helmet.

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

117

Page 50
Image 50
Kirby 37 appendix 117