SERVICE MANUAL
Malfunction |
| Check |
|
|
|
| |
TIMER does not operate | 1. Check the VARIABLE RESISTOR for |
| |
|
| correct operation and install a new part if |
|
|
| necessary. |
|
| 2. | Move the TIMER BUTTON forward and |
|
|
| backward; use a DVM to check for changes |
|
|
| in W. |
|
| 3. | Energize the projector and move the TIMER |
|
|
| to “S”. |
|
|
| • Check the voltages on CR3, Q3, and |
|
|
| Q4, see the voltage table. |
|
|
|
|
|
DARK SHUTTER SWITCH does not operate | 1. | Energize the projector and release the |
|
|
| DARK SHUTTER to allow projection. |
|
| 2. | Check for continuity between PINS 4 and 5 |
|
|
| on the SPECIAL APPLICATIONS PLUG. |
|
| 3. | Press the “FORWARD” or “REVERSE” |
|
|
| BUTTONS to close the DARK SHUTTER. |
|
| 4. | In the closed position, the DVM should |
|
|
| measure 0 W. |
|
| 5. | If this procedure does not correct the |
|
|
| malfunction, install a new DARK SHUTTER |
|
|
| SWITCH. |
|
|
|
| |
After the FOCUS MOTOR energizes and | 1. Remove R3 and install a new 68K W 1/4 W |
| |
moves, the FOCUS MOTOR oscillates. |
| RESISTOR (part 220040). |
|
| 2. | If there is still a malfunction, install a new |
|
|
| PHOTOCELL. |
|
|
|
|
|
|
|
|
|
Focus Malfunctions |
|
|
|
Malfunction |
| Check |
|
| |
No manual focus | 1. Check the FOCUS SHAFT SPRING for the | |
|
| correct tension. |
| 2. | Check the LENS SUPPORT SPRING for |
|
| correct tension. |
| 3. | Check the LENS DRIVE GEAR on the |
|
| FOCUS SHAFT ASSEMBLY for damage |
|
| and install a new part if necessary. |
|
| |
No remote focus (Non Auto Focus models) | 1. Check the REMOTE CORD for damage; | |
|
| use a REMOTE CORD that has no |
|
| damage. |
| 2. | Actuate and hold the REMOTE CONTROL. |
| 3. | Check that the voltage across the FOCUS |
|
| MOTOR is 6.7 V AC. If the voltage is |
|
| correct, install a new FOCUS MOTOR. |
| 4. | Check that the secondary voltage on the |
|
| MAIN MOTOR is correct. |
|
|
|
48 | 18NOV97 – |