SERVICE MANUAL
Section 1: Replacements and Installations
Replacing the LOWER HOUSING ASSEMBLY
Warning
Dangerous Voltage
[1]Disconnect the main power.
[2]Remove the PROJECTION LENS.
[3]Remove the LAMP MODULE ASSEMBLY.
[4]Remove the 6 Torx SCREWS from the LOWER HOUSING ASSEMBLY.
[5]Pull the LOWER HOUSING ASSEMBLY off the TOP HOUSING.
Installing the LOWER HOUSING ASSEMBLY
[1]Do the replacement procedure for the LOWER HOUSING ASSEMBLY in reverse order.
LOWER HOUSING
SCREW (6)
A100_0030HCA
A100_0030HA
LAMP MODULE
Replacing the FAN SHAFT ASSEMBLY
Warning
Dangerous Voltage
[1]Disconnect the main power.
[2]Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3]Cut the 3 WIRE TIES:
•1 on BLOWER COVER wires
•2 on SMALL CIRCUIT BOARD between the MOTOR and MECHANISM ASSEMBLY
4 | 18NOV97 – |