Adjustments

Warning

Dangerous Voltage

[4]Energize the projector.

[5]Set the projector to the LO-LAMP position.

[6]Install and hold the AUTO FOCUS TARGET SLIDE TL-3002 until it is fully seated in the GATE MECHANISM.

[7]Look through the PROJECTION LENS hole and observe the focus light path on the AUTO-FOCUS TARGET SLIDE TL-3002. Check that the light path is correct. If not, do the adjustment procedure for the FOCUS LIGHT PATH.

Warning

Dangerous Voltage

[8]Disconnect the main power.

[9]Heat the 2 POSTS on the PHOTOCELL HOUSING to allow the POSTS to bend enough to pull the PHOTOCELL CIRCUIT BOARD up and off the PHOTOCELL HOUSING. Use a

SOLDERING IRON.

[10]Remove the 2 Wratten FILTERS and the

PHOTOCELL MASK.