Capabilities will vary according to Kilowatt Derating following.
Motor |
| Starting | Running |
Requirements | |||
(HP) |
| Watts | Watts |
1/4 |
| 750 | 330 |
1/3 |
| 1000 | 400 |
1/2 |
| 1500 | 600 |
3/4 |
| 2000 | 750 |
1 |
| 3300 | 1100 |
2 |
| 4000 | 2000 |
3 |
| 5000 | 3000 |
| Figure | ||
|
|
| “Power to |
|
| Will Operate Air | Spare” for |
|
| Lighting | |
Model | Wattage | Conditioner of | Appliances, |
Size Indicated | Tools | ||
4CZ | 4000 | One 13,500 Btu | 2100 |
6.5 CZ | 6500 | One 13,500 Btu | 4600 |
|
| Two 13,500 Btu | 2700 |
Figure 6-2. Air Conditioner Requirements (50 Hz units will have slightly lower “power to spare” figures than those indicated)
Appliance Loads
Marine generator sets are often used to furnish AC for appliances such as TV, stereo, electric water heaters, etc. With the exception of the
Kilowatt Derating
Units are rated as listed below at 1.0 power factor. Derate the listed rating by approximately 3.5% per 1000 ft. (300 m) when the unit is operated at altitudes of 500 ft. (150 m) or more above sea level.
3.5CFZ, 50 Hz: 3.5 kW at 77_F (25_C) and 3.5 kW at 122_F (50_C).
4CZ, 60 Hz: 4 kW at 77_F (25_C) and 3.5 kW at 122_F (50_C).
5CFZ, 50 Hz: 5 kW at 77_F (25_C) and 4.85 kW at 122_F (50_C).
6.5CZ, 60 Hz: 6.5 kW at 77_F (25_C) and 6 kW at 122_F (50_C).
| Motor |
|
Electrical | Starting | Running |
Appliance | Watts | Watts |
Automatic Pilot | ||
Blanket, Electric | ||
Blender | 800 | 600 |
Broiler | 1350 | |
Depthometer | ||
Drill, 3/8” | 600 | 350 |
Dryer, Hair | ||
Fan, Air | ||
Circulating |
|
|
Food, Mixer | 400 | 235 |
Heater, Space | ||
Heater, Water | 1500 | |
Iron | ||
Light Bulbs | (as indicated) | |
Pan, Frying | 1200 | |
Percolator, | 650 | |
Coffee |
|
|
Radar | ||
Radio | ||
Radiophone | ||
Range, Electric | ||
(per element) |
|
|
Soldering Gun | 250 | |
Television | ||
Toaster | ||
Water System |