Kohler 3.5CFZ, 4CZ, 5CFZ, 6.5CZ Appliance Loads, Kilowatt Derating, Motor, Running, Requirements

Models: 3.5CFZ, 4CZ, 5CFZ, 6.5CZ

1 81
Download 81 pages 39.68 Kb
Page 64
Image 64

Capabilities will vary according to Kilowatt Derating following.

Motor

 

Starting

Running

Requirements

(In-Rush)

(HP)

 

Watts

Watts

1/4

 

750

330

1/3

 

1000

400

1/2

 

1500

600

3/4

 

2000

750

1

 

3300

1100

2

 

4000

2000

3

 

5000

3000

 

Figure 6-1. Motor Requirements

 

 

 

“Power to

 

 

Will Operate Air

Spare” for

 

 

Lighting

Model

Wattage

Conditioner of

Appliances,

Size Indicated

Tools

4CZ

4000

One 13,500 Btu

2100

6.5 CZ

6500

One 13,500 Btu

4600

 

 

Two 13,500 Btu

2700

Figure 6-2. Air Conditioner Requirements (50 Hz units will have slightly lower “power to spare” figures than those indicated)

Appliance Loads

Marine generator sets are often used to furnish AC for appliances such as TV, stereo, electric water heaters, etc. With the exception of the resistance-type loads such as the water heater, requirements for appliances are usually low. Such loads must not, however, be overlooked when figuring total requirements. Reserve capacity should be available for anticipated appliance loads to avoid overloading of a set. The average power requirements of some common electrical appliances are given in Figure 6-3.

Kilowatt Derating

Units are rated as listed below at 1.0 power factor. Derate the listed rating by approximately 3.5% per 1000 ft. (300 m) when the unit is operated at altitudes of 500 ft. (150 m) or more above sea level.

3.5CFZ, 50 Hz: 3.5 kW at 77_F (25_C) and 3.5 kW at 122_F (50_C).

4CZ, 60 Hz: 4 kW at 77_F (25_C) and 3.5 kW at 122_F (50_C).

5CFZ, 50 Hz: 5 kW at 77_F (25_C) and 4.85 kW at 122_F (50_C).

6.5CZ, 60 Hz: 6.5 kW at 77_F (25_C) and 6 kW at 122_F (50_C).

 

Motor

 

Electrical

Starting

Running

Appliance

Watts

Watts

Automatic Pilot

--

150--250

Blanket, Electric

--

50--250

Blender

800

600

Broiler

--

1350

Depthometer

--

25--1000

Drill, 3/8”

600

350

Dryer, Hair

--

850--1200

Fan, Air

50--200

25--100

Circulating

 

 

Food, Mixer

400

235

Heater, Space

--

750--1500

Heater, Water

--

1500

Iron

--

900--1200

Light Bulbs

--

(as indicated)

Pan, Frying

--

1200

Percolator,

--

650

Coffee

 

 

Radar

--

750--1500

Radio

--

50--100

Radiophone

--

100--200

Range, Electric

--

1000--1500

(per element)

 

 

Soldering Gun

--

250

Television

--

300--750

Toaster

--

750--1200

Water System

500--1500

300--1250

Figure 6-3. Appliance Average Wattage Ratings

(60 Hz)

6-2 Installation

TP-5695 12/93

Page 64
Image 64
Kohler 3.5CFZ, 4CZ, 5CFZ, 6.5CZ Appliance Loads, Kilowatt Derating, Motor, Running, Requirements, In-Rush, Watts, Lighting