Clearing a Media Misfeed from the Fuser Unit

1 Pull the lever, and then open the right side cover.

" Before opening the right side cover, fold up Tray 1.

2 Push up the levers of the fuser unit cover, and then open the cover.

3 Carefully pull out the misfed media.

188

Clearing Media Misfeeds