11.1 Default Communication Parameters

RS-232

Protocol

3000 (Default)

Legacy

 

 

 

Baud Rate:

115,200

9,600

 

 

 

Data Bits:

8

8

 

 

 

Stop Bits:

1

1

 

 

 

Parity:

None

None

 

 

 

Command Format:

ASCII

ASCII

 

 

 

Example (Set display mode to Picture in Picture):

#Y 0,110,1<CR>

>Y 0 110 1<CR>

 

 

 

Ethernet

To reset the IP settings to the factory reset values, power cycle the device while holding in the Ethernet Reset button, located on the rear panel of the unit

IP Address:

192.168.1.39

 

 

Subnet mask:

255.255.000.000

 

 

Default gateway:

000.000.000.000

 

 

TCP Port #:

5000

 

 

UDP Port #:

50000

Maximum UDP Ports:

10

 

 

Maximum TCP Ports:

4

 

 

Full Factory Reset

 

 

 

Front panel buttons

Turn power off. Turn power on again while holding the RESET TO

 

XGA/720p front panel button. The LEDs blink. Full factory reset is

 

complete once the LEDs cease to blink and react normally

OSD

Factory Reset through the Misc menu item

Protocol 3000

Use “Factory” command or #Y 0,760,1<CR>

 

 

11.2 Input Resolutions

This section defines the input resolutions for each input

11.2.1PC Input Resolutions

PC Input Resolutions

640X480_60

800x600_75

625_P50

1280x1024_60

1400x1050_75

640x480_72

800x600_85

525_P60

1280x1024_75

1600x900_60

 

 

 

 

 

640x480_75

1024x768_60

720_P50

1280x1024_85

1600x1200_60

640x480_85

1024x768_70

720_P60

1360x768_60

1680x1050_60

 

 

 

 

 

800x600_56

1024x768_75

1280x800_60

1366x768_60

1920x1200_60RB

 

 

 

 

 

800x600_60

1024x768_85

1280x960_85

1440x900_60

1080_P50

800x600_72

1152x864_75

1280x768_60

1400x1050_60

1080_P60

 

 

 

 

 

58

VP-770 - Technical Specifications

 

 

Page 63
Image 63
Kramer Electronics VP-770 user manual Default Communication Parameters, PC Input Resolutions