ROUTINE MAINTENANCE
Inspect your stove or insert at minimum frequency stated until you establish a minimum frequency required for your installation (frequency will vary depending upon fuel BTU value / ash content, usage, and misc. installation vari- ables).
ROUTINE CLEANING
Stove will need to be shut off and cooled enough to han- dle before routine cleaning is performed. All ash removal and cleaning should be done while stove is cold. Always disconnect power before doing any routine cleaning.
Proper Disposal of Ashes
Ashes should be placed in a metal container with a tight fit- ting lid. The closed container of ashes should be placed on a
The following areas need to be inspected during Routine Cleaning:
•UltraGrateTM
•Ash Pan
•Ash Trap and Baffles
•Heat Exchange Tubes
•Exhaust Passages and Vent Pipe
UltraGrateTM
The UltraGrateTM should be inspected periodically to assure that the air holes have not become clogged with ash or clinkers. The UltraGrateTM can easily be cleaned with the grate scraper tool, or it can be removed for cleaning. It is very important to monitor the ash build up under the Ultra- GrateTM, as excessive amounts of ash will block combus- tion air from entering the UltraGrateTM, causing pellets to
UltraGrateTM
ASH PAN (Advantage II-T C FS)
The ash pan will have to be emptied periodically, de- pending on the amount of fuel consumed. To access fol- low steps one through four:
1.Open the glass door, then, using the ash pan / grate scraper tool, lift the UltraGrateTM out and sweep the top ash into the pan below.
2.Remove the ash pan cover located below the door by pulling forward until magnets release.
3.Pull the ash pan door knob and swing open.
4.Remove the ash pan using the ash pan / grate scraper tool. (See picture below)
5.Place ashes into a
Pull Forward To Remove Ash Pan Cover
Open Ash Pan Door and Remove Ash Pan Using The
Ash Pan / Grate Scraper Tool
Minimum Frequency of 2 days – 2 weeks
Minimum Frequency of 1 day – 2 weeks
PAGE 26