PLANNING YOUR INSTALLATION
Clearances to combustibles are determined from testing to applicable standards for allow- able heat transfer. The clearances allowed as shown here, do not take into account opera- tion or serviceability requirements.
CLEARANCES
Advantage
MINIMUM CLEARANCES TO COMBUSTIBLES
Advantage | Manufactured (Mobile) Home | |
FS | or Residential Installation | |
▪ Clearance to | Horizontal Flue – Di- | Interior Vertical Flue |
rectly Through Wall |
| |
Combustibles | inch / millimeter | inch / millimeter |
|
|
|
A - Sidewall to unit | ♦6” / 153 mm | ♦6” / 153 mm |
B – Backwall to unit | *2” / 50 mm | 9” / 230 mm |
C – Sidewall to unit | *2” / 50 mm | *2” / 50 mm |
Corner |
|
|
D - Alcove to Fuel | 6” / 150 mm | 6” / 150 mm |
Hopper |
|
|
E – Max. Depth of | •16” / 406 mm | •16” / 406 mm |
Alcove |
|
|
F – Flue to Wall | n / a | 3” / 77 mm |
♦Measured to fuel hopper
•Alcove Requirements – Minimum Height 50” / 127 cm Minimum Width 36” / 966 mm Maximum. Depth 16" / 406 mm
Alcove - Advantage II-T C FS *B
E
DD
Parallel Wall - Advantage II-T C FS
F
*B
A
Minimum clearances specified may not allow for ease of operation and maintenance (please take this in to account when planning the installation).
Corner - Advantage II-T C FS
If installed to the minimum clearances, removal of the appliance may be necessary for servicing.
•Recommended clearance zone from the front of the appliance to combustibles is 4 feet minimum.
*The certified back wall clearance as shown on the listing label is 1" (see Safety / Listing Label) but for proper hopper lid operation in corner and parallel installations a 2" clearance is required.
F
F
C
C
PAGE 6
www.PelletKing.com