Lennox Hearth II-T C INS, II-T C FS Minimum Clearances To Combustibles, Advantage II-TC

Models: II-T C FS II-T C INS

1 48
Download 48 pages 20.4 Kb
Page 6
Image 6
CLEARANCES

PLANNING YOUR INSTALLATION

Clearances to combustibles are determined from testing to applicable standards for allow- able heat transfer. The clearances allowed as shown here, do not take into account opera- tion or serviceability requirements.

CLEARANCES

Advantage II-T C FS - Standard residential or manufac- tured (mobile) home installation. These appliances re- quire the following minimum clearances to combustibles:

MINIMUM CLEARANCES TO COMBUSTIBLES

Advantage II-T C

Manufactured (Mobile) Home

FS

or Residential Installation

Clearance to

Horizontal Flue – Di-

Interior Vertical Flue

rectly Through Wall

 

Combustibles

inch / millimeter

inch / millimeter

 

 

 

A - Sidewall to unit

6” / 153 mm

6” / 153 mm

B – Backwall to unit

*2” / 50 mm

9” / 230 mm

C – Sidewall to unit

*2” / 50 mm

*2” / 50 mm

Corner

 

 

D - Alcove to Fuel

6” / 150 mm

6” / 150 mm

Hopper

 

 

E – Max. Depth of

16” / 406 mm

16” / 406 mm

Alcove

 

 

F – Flue to Wall

n / a

3” / 77 mm

Measured to fuel hopper

Alcove Requirements – Minimum Height 50” / 127 cm Minimum Width 36” / 966 mm Maximum. Depth 16" / 406 mm

Alcove - Advantage II-T C FS *B

E

DD

Parallel Wall - Advantage II-T C FS

F

*B

A

Minimum clearances specified may not allow for ease of operation and maintenance (please take this in to account when planning the installation).

Corner - Advantage II-T C FS

If installed to the minimum clearances, removal of the appliance may be necessary for servicing.

Recommended clearance zone from the front of the appliance to combustibles is 4 feet minimum.

*The certified back wall clearance as shown on the listing label is 1" (see Safety / Listing Label) but for proper hopper lid operation in corner and parallel installations a 2" clearance is required.

F

F

C

C

PAGE 6

www.PelletKing.com

Page 6
Image 6
Lennox Hearth II-T C INS, II-T C FS Minimum Clearances To Combustibles, Alcove - Advantage II-TC FS *B