Lennox Hearth II-T C FS, II-T C INS operation manual Care And Operation, Control Board Operation

Models: II-T C FS II-T C INS

1 48
Download 48 pages 20.4 Kb
Page 21
Image 21
CARE AND OPERATION

CARE AND OPERATION

CONTROL BOARD OPERATION

Start Button – The push button Start Button activates the room air and the exhaust blowers. If the exhaust temperature does not reach operating temperature within 30 minutes, the stove will automatically shut down. The blowers can be restarted by pushing the Start Button again.

Auger On/Off Button – The Auger On/Off Button acti- vates the fuel feed (auger motor) only. The light located just above the button will blink when the auger is turning. The Start Button has to be activated to give power to the Auger On/Off Button. When the Auger On/Off Button is pressed a second time, the pellet feed will stop and the blowers will continue to operate until the stove has cooled sufficiently.

Heat Output Button – When not using a wall thermo- stat, the Heat Output Button provides the ability to burn at five separate settings. The Heat Output Button regu- lates the fuel feed setting and the combustion air supply simultaneously.

Blower Speed Button – The Blower Speed Button con- trols the speed of the Room Air Blower. Pressing this button will increase or decrease the amount of heat exit- ing the stove. THE BLOWER SPEED MUST BE AT THE MAXIMUM #5 SETTING WHEN THE HEAT OUTPUT BUTTON IS ON THE #5 POSITION.

Combustion Air Trim – The Combustion Air (exhaust blower) Trim is located just above the Heat Output Se- lector button. Turning the Trim Control counterclockwise will decrease the amount of combustion air entering the UltraGrate. The Trim Control is factory set at the (0) position.

Auger Trim Control – The Pellet Feed (Auger Trim) Control is located just above the Auger On/Off Button. Turning the Trim Control counterclockwise will decrease the amount of fuel delivered to the UltraGrateTM. Turning the control clockwise will increase the amount of fuel de- livered to the UltraGrateTM. The trim control is factory set at the (0) position.

NOTE: The trim controls should be adjusted for the proper flame as a last resort. Always adjust the damper control first. See Damper Operation, on page 23.

PAGE 21

Control Board

www.PelletKing.com

Page 21
Image 21
Lennox Hearth II-T C FS, II-T C INS operation manual Care And Operation, Control Board Operation