Use PVC primer and solvent cement or ABS solvent cement meeting ASTM specifications, refer to Table 4. As an alter- nate, use all purpose cement, to bond ABS, PVC, or CPVC pipe when using fittings and pipe made of the same materi- als. Use transition solvent cement when bonding ABS to ei- ther PVC or CPVC.
Low temperature solvent cement is recommended. Metal or plastic strapping may be used for vent pipe hangers. Uni- formly apply a liberal coat of PVC primer for PVC or use a clean dry cloth for ABS to clean inside socket surface of fit- ting and male end of pipe to depth of fitting socket.

Canadian Applications Only − Pipe, fittings, primer and solvent cement used to vent (exhaust) this ap- pliance must be certified to ULC S636 and supplied by a single manufacturer as part of an approved vent (ex- haust) system. When bonding the vent system to the fur- nace, use ULC S636 approved One−Step Transition Ce- ment to bond the pipe to the flue collar, or to bond the 90° elbow or reducing 90° elbow to the flue collar. In addi- tion, the first three feet of vent pipe from the furnace flue collar must be accessible for inspection.

Table 5 lists the available exhaust termination kits, as well as vent pipe equivalencies which must be used when siz- ing vent pipe. All Lennox vent terminations are PVC.

TABLE 5

OUTDOOR TERMINATION KITS AND CORRESPONDING EQUIVALENCIES

 

 

 

 

Vent Pipe Length Equivalency (feet)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ex-

Outdoor Ex-

 

 

 

 

 

 

 

VENT

haust Accel-

haust Accel-

1−1/2"

2" Con-

3" Con-

2" Wall Plate

3" Wall Plate

2" Wall

 

erator

erator

Concentric

UNIT

PIPE

centric Kit

centric Kit

Kit

Kit

Ring Kit

MODEL

DIA.

(Dia. X

(Dia. X

Kit

 

 

 

 

 

 

(in.)

Length)

Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1−1/2" X 12"

2" X 12"

71M80

69M29

60L46

22G44

44J40

15F74

 

 

or 44W92

or 44W92

or 44W93

or 30G28

or 81J20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

4

Not

12

Not

Not

4

4*

4

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

2−1/2

5

Not

15

Not

Not

5

5*

5

 

Allowed

Allowed

Allowed

36B−045

 

 

 

 

 

 

3

7

Not

21

Not

Not

7

7*

7

 

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

4

14

Not

42

Not

Not

14

14*

14

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

2

4

Not

12

Not

Not

4

4*

4

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

2−1/2

5

Not

15

Not

Not

5

5*

5

36B−070

Allowed

Allowed

Allowed

 

 

 

 

 

 

36B−071

3

8

Not

24

Not

Not

8

8*

8

 

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

4

14

Not

42

Not

Not

14

14*

14

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

2

Not

1

Not

3

3

Not

1

1**

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

48C−090

2−1/2

Not

2

Not

6

6

Not

2

2**

Allowed

Allowed

Allowed

 

 

 

 

 

 

60C−090

 

 

 

 

 

 

 

Not

 

Not

 

 

Not

 

 

60C−091

3

2

6

6

2

2**

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

4

Not

4

Not

12

12

Not

4

4**

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

2−1/2

Not

2

Not

6

6

Not

2

2

 

Allowed

Allowed

Allowed

48C−110

 

 

 

 

 

 

3

Not

2

Not

6

6

Not

2

2

60C−110

Allowed

Allowed

Allowed

60C−111

 

 

 

 

 

 

 

4

Not

4

Not

12

12

Not

4

4

 

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

3

Not

6

Not

Not

15

Not

6

Not

 

Allowed

 

Allowed

Allowed

Allowed

Allowed

 

 

 

 

 

60D−135

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Not

10

Not

Not

25

Not

10

Not

 

 

Allowed

 

Allowed

Allowed

Allowed

Allowed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Requires field−provided and installed 1−1/2" exhaust accelerator. **Requires field−provided and installed 2" exhaust accelerator.

Termination kits 44W92 (includes 1−1/2" reducer), 44W93, 30G28 and 81J20 approved for use in Canadian installations.

Page 17

Page 17
Image 17
Lennox International Inc G61MP Series Units, Gas Units Outdoor Termination Kits and Corresponding Equivalencies, Model DIA

G61MP Series Units, Gas Units specifications

Lennox International Inc. has established itself as a leader in the heating and cooling industry, and its G61MP Series Gas Units stand as a testament to the company's commitment to innovation and energy efficiency. These gas units are specifically designed for residential applications and are recognized for their reliability, performance, and advanced technology.

One of the main features of the G61MP Series is its variable speed motor, which offers significantly enhanced comfort over traditional single-stage gas units. This technology allows for precise temperature control and improved humidity management. By adjusting its speed according to the heating demand, the unit minimizes temperature fluctuations, leading to a more consistent indoor climate.

Another notable characteristic of the G61MP Series is its ECM blower motor, which operates quietly and efficiently. This motor not only reduces energy consumption but also enhances the overall comfort of the home by providing a steady flow of warm air without the disruptive noise often associated with traditional gas units.

The G61MP Series units are designed with a focus on energy efficiency, boasting an impressive Annual Fuel Utilization Efficiency (AFUE) rating. This rating indicates that these units convert a significant portion of the fuel they consume into usable heat, resulting in lower energy bills for homeowners. The units are equipped with a modulating gas valve that further optimizes fuel usage by adjusting the gas flow according to the heating needs of the home.

Safety is a paramount consideration in the design of the G61MP Series. These units are built with advanced safety features, including a self-diagnostic control system that continuously monitors the unit’s performance. This system alerts homeowners to any potential issues, allowing for proactive maintenance and ensuring the longevity of the equipment.

The G61MP Series is also designed for ease of installation and servicing. Its compact design allows for flexible placement in various home environments, while the user-friendly access panels simplify routine maintenance tasks.

In conclusion, Lennox International Inc.'s G61MP Series Gas Units deliver a combination of advanced technology, energy efficiency, and reliability, making them an excellent choice for homeowners looking to enhance their heating systems. With features designed to maximize comfort, minimize energy costs, and ensure safety, these units represent a significant advancement in residential heating solutions.