Troubleshooting: Heating Sequence of Operation (Continued)
HEATING SEQUENCE OF OPERATION
CONTINUED
THERMOSTAT CALLS FOR HEAT.
STATUS LED −− HEARTBEAT.
SEE BOX A.
FLAME SIGNAL ABOVE
(u1.40 microamps)
YES
YES
SINGLE−STAGE THERMOSTAT MODE (DIP SWITCH SET AT
YES
START SECOND−STAGE RECOGNITION ON DELAY (10 OR 15 MINUTES).
STATUS LED −− HEARTBEAT
ROLLOUT SWITCHES CLOSED?
YES
FIRST−STAGE (LOW FIRE)
PRESSURE SWITCH CLOSED?
NO
LOW FLAME SIGNAL
(Does not affect control operation) STATUS ERROR CODE 1 + 2.
TWO STAGE THERMOSTAT MODE (DIP SWITCH SET AT
YES
|
|
|
| 45−SECOND INDOOR BLOWER ON DELAY BEGINS. |
| |||
|
|
|
| STATUS LED −− HEARTBEAT. |
| |||
|
|
|
| YES |
|
|
| |
YES |
|
|
| NO | ||||
PRIMARY & SECONDARY LIMIT SWITCHES | ||||||||
| ||||||||
|
|
|
| CLOSED? |
| |||
NO |
|
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
|
| GAS VALVE OFF. COMBUSTION AIR INDUCER ON. |
| |||
|
|
|
|
| ||||
|
|
|
|
| ||||
|
|
|
| INDOOR BLOWER ON. |
| |||
|
|
|
|
| ||||
| YES | STATUS ERROR CODE 5 + 1. SEQUENCE HOLDS |
| |||||
| UNTIL ROLLOUT SWITCH IS RESET AND MAIN |
| ||||||
|
|
|
|
| ||||
|
|
|
| POWER IS INTERRUPTED OR THERMOSTAT |
| |||
|
|
|
| IS CYCLED OFF/ON FOR 3 SECOND MINIMUM. |
|
YES
NO
NO
FIRST−STAGE HEAT DEMAND SATISFIED?
YES
GAS VALVE OFF, COMBUSTION AIR INDUCER
OFF FOLLOWING POST PURGE.
INDOOR BLOWER OFF WITH DELAY
STATUS LED −− PULSE
SECOND−STAGE HEAT DEMAND.
SECOND−STAGE HEAT DEMAND REQUIRED?
YES
SECOND STAGE PRESSURE SWITCH CLOSED?
ABNORMAL FLASH CODE.
NOTE − IF SECOND−STAGE PRESSURE SWITCH
WAS ORIGINALLY FOUND CLOSED,
ABNORMAL CODE WILL FLASH.
NO | YES |
SECOND−STAGE 30−SECOND DELAY ON BEGINS.
STATUS LED −− HEARTBEAT.
YES
SECOND−STAGE COMBUSTION AIR INDUCER ON. SECOND−STAGE GAS VALVE ON. HIGH HEAT INDOOR BLOWER SPEED ON. STATUS LED −− HEARTBEAT.
YES
SECOND−STAGE PRESSURE SWITCH CLOSED
IN LESS THAN TEN (10) SECONDS?
STATUS LED −− HEARTBEAT
YES
CONTINUED ON NEXT PAGE
GAS VALVE OFF, COMBUSTION AIR INDUCER OFF, |
| ||
INDOOR BLOWER ON. |
| ||
STATUS ERROR CODE 3 + 1. |
| ||
|
| YES | |
HAS PRIMARY OR SECONDARY LIMIT | |||
SWITCH CLOSED WITHIN 3 MINUTES? |
| ||
(Indoor blower on low speed during 3−minute period) |
| ||
|
| ||
NO |
|
| |
|
|
| |
LIMIT SWITCH WATCHGUARD MODE. |
| ||
GAS VALVE OFF, COMBUSTION AIR INDUCER OFF, |
| ||
INDOOR BLOWER OFF WITH DELAY. | YES | ||
STATUS ERROR CODE 4 + 5 | |||
| |||
IS 60−MINUTE RESET PERIOD COMPLETE? |
|
GAS VALVE OFF. COMBUSTION AIR INDUCER ON. INDOOR BLOWER OFF AFTER DELAY.
STATUS ERROR CODE 2 + 3. CONTROL RESTARTS YES IGNITION SEQUENCE IF PRESSURE SWITCH
CLOSES WITHIN 2−1/2 MINUTES.
| SECOND−STAGE PRESSURE SWITCH CLOSED | NO | |
| AT BEGINNING OF HEAT DEMAND? | ||
|
| ||
| STATUS ERROR CODE 2 + 6. |
| |
|
|
| |
| SECOND STAGE HEAT DEMAND |
| |
| STATUS LED −− HEARTBEAT. |
| |
| NO |
| |
| RETURNS TO FIRST−STAGE HEAT MODE WHICH |
| |
| CONTINUES UNTIL SECOND−STAGE PRESSURE |
| |
| SWITCH CAN BE PROVEN or HEAT DEMAND IS |
| |
| SATISFIED. FIVE (5) MINUTE WAIT PERIOD |
| |
NO | INITIATED BEFORE RETRY. WERE 5 ATTEMPTS |
| |
MADE FOR SECOND−STAGE HEAT? |
| ||
| YES |
|
|
| CONTINUES FIRST−STAGE HEATING DEMAND. |
| |
| WILL NOT REATTEMPT SECOND−STAGE |
| |
| HEATING DEMAND. |
| |
| STATUS ERROR CODE 2 + 5. |
|
Page 59