9 − One 24V

9 − One 24V

board terminal block. Any humidifier rated up to 0.5 amp can be connected to this terminal with the ground leg of the circuit being connected to either ground or

the

52 for control board config-

uration.

 

10 −Install the room thermostat according to the instruc- tions provided with the thermostat. See table 10 for field wiring connections in varying applications. If the furnace is being matched with a heat pump, refer to the instruction packaged with the dual fuel thermostat.

Indoor Blower Speeds

1 − When the thermostat is set to AN ON," the indoor blower will run continuously on the low heat speed when there is no cooling or heating demand.

2 − When the G61MP is operating in the high−fire or low− fire heating mode, the indoor blower will run on the cor- responding heating speed.

3 − When there is a cooling demand, the indoor blower will run on the corresponding cooling speed.

TYPICAL G61MP FIELD WIRING DIAGRAM

FIGURE 51