Important:Useonlyapprovedtoolsandtestequipment.Somehandtoolshavehandlescoveredwithasoft
materialthatdoesnotinsulateyouwhenworkingwithliveelectricalcurrents.Manycustomershave,near
theirequipment,rubberoormatsthatcontainsmallconductiveberstodecreaseelectrostaticdischarges.
Donotusethistypeofmattoprotectyourselffromelectricalshock.
Findtheroomemergencypower-off(EPO)switch,disconnectingswitch,orelectricaloutlet.Ifanelectrical
accidentoccurs,youcanthenoperatetheswitchorunplugthepowercordquickly.
Donotworkaloneunderhazardousconditionsornearequipmentthathashazardousvoltages.
Disconnectallpowerbefore:
Performingamechanicalinspection
Workingnearpowersupplies
RemovingorinstallingFieldReplaceableUnits
Beforeyoustarttoworkonthemachine,unplugthepowercord.Ifyoucannotunplugit,askthecustomer
topower-offthewallboxthatsuppliespowertothemachineandtolockthewallboxintheoffposition.
Ifyouneedtoworkonamachinethathasexposedelectricalcircuits,observethefollowingprecautions:
Ensurethatanotherperson,familiarwiththepower-offcontrols,isnearyou.
Remember:Anotherpersonmustbetheretoswitchoffthepower,ifnecessary .
Useonlyonehandwhenworkingwithpowered-onelectricalequipment;keeptheotherhandinyour
pocketorbehindyourback.
Remember:Theremustbeacompletecircuittocauseelectricalshock.Byobservingtheaboverule,
youmaypreventacurrentfrompassingthroughyourbody.
Whenusingtesters,setthecontrolscorrectlyandusetheapprovedprobeleadsandaccessoriesfor
thetesters.
Standonsuitablerubbermats(obtainedlocally,ifnecessary)toinsulateyoufromgroundssuchas
metaloorstripsandmachineframes.
Observethespecialsafetyprecautionswhenyouworkwithveryhighvoltages;theseinstructionsarein
thesafetysectionsofmaintenanceinformation.Useextremecarewhenmeasuringhighvoltages.
Regularlyinspectandmaintainyourelectricalhandtoolsforsafeoperationalcondition.
Donotusewornorbrokentoolsandtesters.
Neverassumethatpowerhasbeendisconnect edfromacircuit.First,checkthatithasbeenpowered-off.
Alwayslookcarefullyforpossiblehazardsinyourworkarea.Examplesofthesehazardsaremoistoors,
nongroundedpowerextensioncables,powersurges,andmissingsafetygrounds.
Donottouchliveelectricalcircuitswiththereectivesurfaceofaplasticdentalmirror.Thesurfaceis
conductive;suchtouchingcancausepersonalinjuryandmachinedamage.
Donotservicethefollowingpartswiththepoweronwhentheyareremovedfromtheirnormaloperating
placesinamachine:
Powersupplyunits
Pumps
Blowersandfans
Motorgenerators
andsimilarunits.(Thispracticeensurescorrectgroundingoftheunits.)
Ifanelectricalaccidentoccurs:
Usecaution;donotbecomeavictimyourself.
Switchoffpower.
Sendanotherpersontogetmedicalaid.
4ThinkCentreHardwareMaintenanceManual