Diagnostic Error Code

FRU/Action

 

 

 

001-041-XXXSystem DMA failure

1.

Turn off/on the system and re-test.

 

2.

System board

 

 

001-195-XXXSystem Test aborted by user

Information only Restart the test, if necessary.

 

 

 

001-196-XXXSystem test halt, error threshold exceeded

1.

Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

 

001-197-XXXSystem test warning

1.

Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 41.

 

2.

Re-run test

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

 

001-198-XXXSystem test aborted

1.

If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 41.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS from a disc” on page 180.

 

3.

Go to “Undetermined problems” on page 66.

 

 

 

001-199-XXXSystem test failed, cause unknown

1.

Go to “Undetermined problems” on page 66.

 

2.

Flash the system and re-test.

 

3.

Replace component under function test.

 

 

001-250-XXXSystem ECC error

System board

 

 

001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX

System board

System DMA error

 

 

 

 

001-260-XXX 001-264-XXX System IRQ error

System board

 

 

 

001-268-XXXSystem IRQ1 failure

1.

Device on IRQ1

 

2.

System board

 

 

 

001-269-XXXSystem IRQ2 failure

1.

Device on IRQ2

 

2.

System board

 

 

 

001-270-XXXSystem IRQ3 failure

1.

Device on IRQ3

 

2.

System board

 

 

 

001-271-XXXSystem IRQ4 failure

1.

Device on IRQ4

 

2.

System board

 

 

 

001-272-XXXSystem IRQ5 failure

1.

Device on IRQ5

 

2.

System board

 

 

 

001-273-XXXSystem IRQ6 (diskette drive) failure

1.

Diskette Cable

 

2.

Diskette drive

 

3.

System board

 

 

 

001-274-XXXSystem IRQ7 failure

1.

Device on IRQ7

 

2.

System board

 

 

 

001-275-XXXSystem IRQ8 failure

1.

Device on IRQ8

 

2.

System board

 

 

 

50ThinkCentre Hardware Maintenance Manual