Diagnostic Error Code

FRU/Action

 

 

071-00X-XXX 071-01X-XXX 071-02X-XXXAudio port

1. Run the Setup Utility program.

error

2.

Flash the system. See “Updating (flashing) the BIOS

 

 

 

from a disc” on page 180.

 

3.

System board

 

 

071-03X-XXXAudio port failure

1. Speakers

 

2.

Microphone

 

3.

Audio card, if installed

 

4.

System board

 

 

071-04X-XXXAudio port failure

1. Run the Setup Utility program.

 

2.

Audio card, if installed

 

3.

System board

 

 

071-195-XXXAudio port Test aborted by user

Information only Restart the test, if necessary.

 

 

 

071-196-XXXAudio port test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

071-197-XXXAudio port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 41.

 

2.

Re-run the test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

071-198-XXXAudio port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 41.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS from a disc” on page 180.

 

3.

Go to “Undetermined problems” on page 66.

 

 

071-199-XXXAudio port test failed, cause unknown

1. See “Undetermined problems” on page 66.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS from a disc” on page 180.

 

3.

Replace component under function test.

 

 

071-25X-XXXAudio port failure

1. Speakers

 

2.

Audio card, if installed

 

3.

System board

 

 

080-000-XXXGame Port interface Test Passed

No action

 

 

080-XXX-XXXGame Port interface Error

1. Remove the game port device and re-test the system.

 

 

080-195-XXXGame Port interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

080-196-XXXGame Port interface test halt, error

1.

Press F3 to review the log file.

threshold exceeded

2.

Restart the test to reset the log file.

 

 

 

 

58ThinkCentre Hardware Maintenance Manual

Page 64
Image 64