Diagnostic Error Code

FRU/Action

 

 

 

000-198-XXXBIOS test aborted

1.

Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 41.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS from a disc” on page 180.

 

3.

Go to “Undetermined problems” on page 66.

 

 

 

000-199-XXXBIOS test failed, cause unknown

1.

Go to “Undetermined problems” on page 66.

 

2.

Flash the system and re-test.

 

3.

Replace component under function test.

 

 

 

000-250-XXXBIOS APM failure

1.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

 

000-270-XXXBIOS ACPI failure

1.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

001-000-XXXSystem Test Passed

No action

 

 

001-00X-XXX System Error

System board

 

 

001-01X-XXX System Error

System board

 

 

001-024-XXXSystem Addressing test failure

System board

 

 

 

001-025-XXXSystem Checksum Value error

1.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

 

001-026-XXXSystem FLASH data error

1.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

 

001-027-XXXSystem Configuration/Setup error

1.

Run the Setup Utility program.

 

2.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

3.

System board

 

 

001-032-XXXSystem Device Controller failure

System board

 

 

 

001-034-XXXSystem Device Buffer Allocation failure

1.

Reboot the system

 

2.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

3.

Run memory test

 

4.

System board

 

 

001-035-XXXSystem Device Reset condition detected

System board

 

 

001-036-XXXSystem Register error

System board

 

 

 

001-038-XXXSystem Extension failure

1.

Adapter card

 

2.

System board

 

 

 

001-039-XXXSystem DMI data structure error

1.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

 

001-040-XXXSystem IRQ failure

1.

Turn off/on the system and re-test.

 

2.

System board

 

 

 

Chapter 7. Symptom-to-FRU index 49

Page 55
Image 55