Diagnostic Error Code

FRU/Action

 

 

000-000-XXXBIOS Test Passed

No action

 

 

000-002-XXX BIOS Timeout

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-024-XXXBIOS Addressing test failure

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-025-XXXBIOS Checksum Value error

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-026-XXXFLASH data error

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-027-XXXBIOS Configuration/Setup error

1. Run the Setup Utility program.

 

2.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

3.

System board

 

 

000-034-XXXBIOS Buffer Allocation failure

1. Reboot the system.

 

2.

Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

3.

Run memory test

 

4.

System board

 

 

000-035-XXXBIOS Reset Condition detected

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-036-XXXBIOS Register error

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-038-XXXBIOS Extension failure

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

Adapter card

 

3.

System board

 

 

000-039-XXXBIOS DMI data error

1. Flash the system. See “Updating (flashing) the BIOS

 

 

from a disc” on page 180.

 

2.

System board

 

 

000-195-XXXBIOS Test aborted by user

Information only Restart the test, if necessary.

 

 

000-196-XXXBIOS test halt, error threshold exceeded

1. Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

000-197-XXXBIOS test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 41.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

 

48ThinkCentre Hardware Maintenance Manual

Page 54
Image 54
Lenovo 266, 384, 4168, 5067, 7516, 7519, 5027, 2491 manual Diagnostic Error Code FRU/Action, No action, XXX Bios Timeout