Diagnostic Error Code FRU/Action
001-024-XXX
System Addressingtest failure
System board
001-025-XXX
System Checksum Valueerror 1. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2. System board
001-026-XXX
System FLASH data error 1. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2. System board
001-027-XXX
System Configuration/Setup error 1. Run Setup
2. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3. System board
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device BufferAllocation failure 1. Reboot the system
2. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3. Run memory test
4. System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
001-038-XXX
System Extension failure 1. Adapter card
2. System board
001-039-XXX
System DMI data structure error 1. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2. System board
001-040-XXX
System IRQ failure 1. Power-off/on system and re-test
2. System board
001-041-XXX
System DMA failure 1. Power-off/on system and re-test
2. System board
001-195-XXX
System Testaborted by user
Information only
Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file