Diagnostic Error Code FRU/Action
005-010-XXX
005-011-XXX
005-012-XXX
005-013-XXX
VideoSignal failure
1. Videocard, if installed
2. System board
005-016-XXX
VideoSimple Pattern
test failure
1. VideoRam
2. Videocard, if installed
3. System board
005-024-XXX
VideoAddressing test failure 1. Videocard, if installed
2. System board
005-025-XXX
VideoChecksum Value error 1. Video card, if installed
2. System board
005-027-XXX
VideoConfiguration/Setup error 1. Run Setup
2. Videodrivers update
3. Videocard, if installed
4. System board
005-031-XXX
VideoDevice Cable failure 1. Videocable
2. Monitor
3. Videocard, if installed
4. System board
005-032-XXX
VideoDevice Controller failure 1. Videocard, if installed
2. System board
005-036-XXX
VideoRegister error 1. Videocard, if installed
2. System board
005-038-XXX
System BIOS extension failure 1. Video card, if installed
2. System board
005-040-XXX
VideoIRQ failure 1. Videocard, if installed
2. System board
005-195-XXX
VideoTest aborted by user
Information only
Re-start the test, if necessary
005-196-XXX
Videotest halt, error threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
005-197-XXX
Videotest warning 1. Make sure the component that is called
out is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component called out in
warning statement
4. Replace the component under test
Chapter7. Symptom-to-FRU Index 61