Diagnostic Error Code FRU/Action
015-196-XXX
USB port test halt, error threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
015-197-XXX
USB port test warning 1. Make sure the component that is called
out is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
015-198-XXX
USB port test aborted 1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Go to “Undetermined problems” on page
82
015-199-XXX
USB port test failed, cause unknown 1. Go to “Undetermined problems” on page
82
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Replace component under function test
018-000-XXX
PCI Card TestPassed
No action
018-0XX-XXX
PCI Card Failure 1. Riser card, if installed
2. System board
018-195-XXX
PCI Card Testaborted by user 1. PCI card
2. Information only
Re-start the test, if necessary
018-196-XXX
PCI Card test halt, error threshold exceeded 1. PressF3 to review the log file
2. Re-start the test to reset the log file
018-197-XXX
PCI Card test warning 1. Make sure the component that is called
out is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
66 HardwareMaintenance Manual