Diagnostic Error Code FRU/Action
014-198-XXX
Parallel port test aborted 1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Go to “Undetermined problems” on page
82
014-199-XXX
Parallel port test failed, cause unknown 1. Go to “Undetermined problems” on page
82
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Replace component under function test
014-2XX-XXX
014-3XX-XXX
Parallel port failure
1. External parallel device
2. System board
015-000-XXX
USB port Interface TestPassed
No action
015-001-XXX
USB port Presence 1. Remove USB device(s) and re-test
2. System board
015-002-XXX
USB port Timeout 1. Remove USB device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback failure 1. Remove USB device(s) and re-test
2. System board
015-027-XXX
USB port Configuration/Setup error 1. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2. System board
015-032-XXX
USB port Device Controller failure
System board
015-034-XXX
USB port buffer
allocation failure
1. Reboot the system
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Run memory test
4. System board
015-035-XXX
USB port Reset condition detected 1. Remove USB device(s) and re-test
2. System board
015-036-XXX
USB port Register error
System board
015-040-XXX
USB port IRQ failure 1. Run setup and check for conflicts
2. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3. System board
015-195-XXX
USB port Testaborted by user
Information only
Re-start the test, if necessary
Chapter7. Symptom-to-FRU Index 65