Diagnostic Error Code FRU/Action
080-XXX-XXX
Game Port interface Error 1. Remove the game port device and
re-test the system
080-195-XXX
Game Port interface Testaborted by user
Information only
Re-start the test, if necessary
080-196-XXX
Game Port interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
080-197-XXX
Game Port interface test warning 1. Make sure the component that is called
out is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
080-198-XXX
Game Port interface test aborted 1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Go to “Undetermined problems” on page
82
080-199-XXX
Game Port interface test failed, cause
unknown
1. See “Undetermined problems” on page
82
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Replace component under function test
086-000-XXX
Mouse Port interface TestPassed
No action
086-001-XXX
Mouse Port interface Presence 1. Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller
failure
1. Mouse
2. System board
086-035-XXX
Mouse Port interface Reset 1. Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure 1. Run Setup
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Testaborted by user
Information only
Re-start the test, if necessary
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
72 HardwareMaintenance Manual