Diagnostic Error Code FRU/Action
011-000-XXX
Serial port Interface TestPassed
No action
011-001-XXX
Serial port Presence 1. Remove external serial device, if
present
2. Run setup, enable port
3. System board
011-002-XXX
011-003-XXX
Serial port Timeout/Parityerror
System board
011-013-XXX
011-014-XXX
Serial port Control Signal/Loopback test
failure
System board
011-015-XXX
Serial port External Loopback failure 1. Wrapplug
2. System board
011-027-XXX
Serial port Configuration/Setup error 1. Run Setup, enable port
2. Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3. System board
011-03X-XXX
011-04X-XXX
Serial port failure
System board
011-195-XXX
Serial port Testaborted by user
Information only
Re-start the test, if necessary
011-196-XXX
Serial port test halt, error threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
011-197-XXX
Serial port test warning 1. Make sure the component that is called
out is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
011-198-XXX
Serial port test aborted 1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Go to “Undetermined problems” on page
82
Chapter7. Symptom-to-FRUIndex 63