Diagnostic Error Code FRU/Action
175-195-XXX
Thermal Sensor(s) Testaborted by user
Information only
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning 1. Make sure the component that is called
out is connected and/or enabled. See
Chapter6, “Using the Setup Utility,” on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
175-198-XXX
Thermal Sensor(s) test aborted 1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Go to “Undetermined problems” on page
82
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page
82
2. Flash the system and re-test. See
“Updating (flashing) BIOS from a
CD-ROM or diskette” on page 786
3. Replace component under function test
175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error
1. Check fans
2. Check Power supply voltages
3. Microprocessor
4. System board
185-000-XXX
Asset Security TestPassed
No action
185-XXX-XXX
Asset Security failure 1. Flash system
2. System board
185-278-XXX
Asset Security Chassis Intrusion 1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX
System Memory TestPassed
No action
201-XXX-XXX
System Memory error 1. Replacethe memory module called out
by the test
2. System board
202-000-XXX
System Cache TestPassed
No action
202-XXX-XXX
System Cache error 1. Cache, if removable
2. System board
3. Microprocessor
Chapter7. Symptom-to-FRU Index 75