Glycol/GLYCOOL Cooled Models

Figure 18 GLYCOOL general arrangement

 

Expansion Tank Field Installed at

 

 

 

Highest Point in System

 

 

Unions*

 

Fill *

Drycooler

Drycooler

 

 

 

 

 

 

Electric

 

 

 

 

Box

Coil

 

 

 

 

 

 

 

 

 

 

Fluid

 

 

 

Pressure

 

Return to

Isolation

 

Port*

Unions*

Pump

 

Valves*

 

 

Fluid

 

 

 

 

 

 

 

 

 

 

Supply

 

 

 

Hose

 

from

 

 

Air Vents*

 

Pump

 

 

Bib*

 

 

 

 

at Top of

Flow Regulating

Sight

 

 

 

Risers

 

Valve*

 

Glass

 

 

 

Pressure

 

 

 

Port*

Filter

Drier

Hot Gas

Bypass

Solenoid

Valve

Hot Gas

Bypass

3-Way Water

Regulating

FluidValve

Valve

Supply to

Glycol

Pump

Pump

Housing

Evaporator

Coil

Expansion

Valve

Sensing

Bulb

Hot Gas

Bypass External

Valve Scroll Equalizers

Compressor

Service

Valves

Econ-O-Coil

Tube

in Tube

Condenser

Unit

Actuator

Fluid

Econ-O-Cycle

 

Return

 

Comparator

 

from

 

Unit

Isolation

3-Way Chilled

 

 

Valves*

Glycol Valve

Econ-O-Coil

Circuit

Hose Bibs*

FACTORY PIPING

 

FIELD PIPING

 

*Components are not supplied by Liebert but

SL-11901 PG 5

are recommended for proper circuit operation and maintenance.

38

Page 44
Image 44
Liebert 3000 installation manual Glycool general arrangement

3000 specifications

The Liebert 3000 is a cutting-edge power protection solution designed to provide reliable and efficient backup power for critical applications. This uninterruptible power supply (UPS) system is engineered to safeguard sensitive electronic equipment from power disturbances, ensuring uninterrupted operations in data centers, telecommunications, and industrial environments.

One of the standout features of the Liebert 3000 is its high-efficiency design. With an efficiency rating of up to 94%, the system minimizes energy loss, resulting in lower operational costs and a reduced carbon footprint. This is particularly important in today's environmentally conscious climate, as organizations strive to meet sustainability goals while maintaining top-tier performance.

The Liebert 3000 employs advanced technologies to enhance its functionality. It incorporates online double-conversion technology, which provides a continuous supply of clean and regulated power. This technology ensures that connected loads receive stable voltage and frequency, shielding them from voltage spikes, sags, and outages. Additionally, the UPS offers features such as automatic battery testing, which helps ensure peak battery performance and reliability.

Another key characteristic of the Liebert 3000 is its modular design, allowing for flexible scalability. This means that organizations can easily expand the capacity of their UPS system as their power needs grow, without the need for extensive system overhauls. The modular architecture also facilitates simplified maintenance and reduces downtime, as individual modules can be serviced without interrupting power to the critical load.

The system is equipped with comprehensive monitoring and management capabilities. The Liebert 3000 provides real-time data on power usage, battery status, and system performance, enabling facility managers to make informed decisions and proactively address potential issues. The integration of remote management tools allows for seamless monitoring from anywhere, providing peace of mind for operators.

Overall, the Liebert 3000 combines high efficiency, advanced technology, and flexible design to deliver a robust power protection solution. Its reliability and performance make it a preferred choice for organizations seeking to protect their critical infrastructure while enhancing operational efficiency and sustainability. As businesses continue to rely on technology for their everyday operations, the Liebert 3000 stands out as a dependable safeguard against the uncertainties of power quality.