Adjusting the door opening angle
Fig. 39

Adjusting the door opening angle

u Remove locking device Fig. 37 (2) by twisting it. u Snap panel Fig. 37 (1) into place on the door.

u Turn cover Fig. 27 (6) 180° from the handle side, place it on top from the outside and snap into place.

8.9 Aligning the door

u Unscrew center screw on lower part of bearing bracket Fig. 32 (20).

u Align the doors flush with the appliance housing using the two oblong holes in the lower bearing bracket Fig. 32 (20) as a guide if needed.

u Tighten the screws fully.

9 Adjusting the door opening angle

The appliance is delivered with a door opening angle of 110°. If the angle needs to be limited to 90° an opening limiter must be used on the soft stop mechanism. Carry out the following steps for all soft stop mechanisms on the appliance (the top soft stop mechanism is illustrated):

Removing the soft stop unit u Open the door.

u Unscrew spacer Fig. 39 (10) .

u Push panel forward over the damper bracket Fig. 39 (4) in the direction of the appliance.

u Engage locking device Fig. 39 (2) into place inside oblong hole.

w The locking device prevents the hinge from snapping shut.

u Unscrew cover that is on the hinge side Fig. 39 (5) until the first notch using a screwdriver.

w The bolt will become visible.

u Push bolt Fig. 39 (3) out from below.

u Press damper bracket Fig. 39 (4) in the direction of the door.

u Completely loosen cover that is on the hinge side Fig. 39 (5) and remove.

u Remove panel Fig. 39 (1).

u Unscrew soft stop unit (2 x Torx 15) Fig. 39 (6).

u Slightly pull out soft stop unit, push it towards the handle side and open it out.

Fit opening limiter:

Fig. 38

NOTICE

Risk of damage!

If the door seal is damaged the door may not close properly and the level of cooling is insufficient.

u Do not damage the door seal with the screwdriver!

u Release panel Fig. 38 (1) using slotted screwdriver and remove.

w The panel hangs above the damper bracket.

Fig. 40 u Fit opening limiter (90°) Fig. 40 (21) supplied: insert it into the soft stop mechanism from the side and push in

until it audibly snaps into place.

Re-attaching the soft stop mechanism:

23