Connecting the appliance

WARNING

Electrical shock hazard!

This appliance is equipped with a three-prong (grounding) polarized plug for your protection against possible shock hazards. Electrical Grounding Required.

u Do not remove the round grounding prong from the plug. u Do not use a two-prong grounding adapter.

-Wait 1 hour after installation before you plug in the appliance. This allows the refrigerant and system lubrication to reach equilibrium.

-Make sure incoming voltage is the same as the appliance rating. A 110-120 Volt, 60 Hz, 15 Amp electrical supply (20 Amp for side-by-side installations) circuit that is controlled by a circuit breaker or fuse is required.

-We recommend using a dedicated circuit for this appliance to prevent electrical overload.

-Follow all Federal, State and local electrical, fire and building codes and ordinances when installing the receptacle and / or the appliance.

-In some communities, a wall switch is required to turn power to the appliance ON and OFF.

-To reduce the risk of fire, electric shock, or personal injury, installation work and electrical wiring must be done by a qualified electrician in accordance with all applicable codes and standards, including fire-rated construction.

-You are advised to clean the appliance before switching it on the first time .

-The top of the electric outlet must be located within 82-5/8 in. (2100 mm) from the top of the base in the cabinet.