b-11

 

OPERATION

b-11

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

Exit Setup Menu

 

 

 

P.0

This setup menu parameter can be used to exit the setup menu. When P.0 is displayed, press

 

 

 

 

the left Mode Select button to exit the setup menu.

 

 

 

 

 

 

 

 

P.1

Wire Feed Speed Units

 

 

 

 

 

This option selects which units to use for displaying wire feed speed.

 

 

 

 

 

English = inches/minute wire feed speed units (default).

 

 

 

 

 

Metric = meters/minute wire feed speed units.

 

 

 

 

 

 

 

 

P.2

Arc Display Mode

 

 

 

 

 

This option selects what value will be shown on the upper left display while welding.

 

 

 

 

 

Amps = The left display shows Amperage while welding (default).

 

 

 

 

 

WFS = The left display shows Wire Feed Speed while welding.

 

 

 

 

 

 

 

 

P.3

Display Options

 

 

 

 

 

This setup parameter was previously named "Display Energy"

 

 

 

 

 

If the previous software revision had this parameter set to display energy, that selection will

 

 

 

 

remain.

 

 

 

 

 

This option selects the information displayed on the alphanumeric displayes while welding. Not

 

 

 

 

all P.3 selections will be available on all machines. In order for each selection to be included in

 

 

 

 

the list, the power source must support that feature. A software update of the power source may

 

 

 

 

be needed to include the features.

 

 

 

 

 

Standard Display = The lower displays will continue to show preset information during and after

 

 

 

 

a weld (default).

 

 

 

 

 

Show Energy = Energy is displayed, along with time in HH:MM:SS format.

 

 

 

 

 

Show Weld Score = The accumulative weld score result is shown.

 

 

 

 

 

 

 

 

P.4

Recall Memory with Trigger

 

 

 

 

 

This option allows a memory to be recalled by quickly pulling and releasing the gun trigger. To

 

 

 

 

recall a memory, quickly pull and release the trigger the number of times that correspond to the

 

 

 

 

memory number. For example, to recall memory 3, quickly pull and release the trigger 3 times.

 

 

 

 

To recall memory 1, quickly pull and release the trigger the number of user memories plus 1.

 

 

 

 

Memories cannot be recalled while the system is welding.

 

 

 

 

 

Disabled = The gun trigger cannot be used to recall user memories (default).

 

 

 

 

 

Enabled = The gun trigger can be used to recall user memories.

 

 

 

 

 

 

 

POWER FEED™ 10M SINGLE WIRE FEEDER

Page 33
Image 33
Lincoln Electric IM915 manual User Defined Parameters