b-15

 

OPERATION

b-15

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

P.99

Show Test Modes

 

 

 

 

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the machine

 

 

 

 

 

does not include test weld modes in the list of weld modes that are available to the operator. To manually

 

 

 

 

 

select a test weld mode, set this option to "Yes". When the power source is turned off and back on again,

 

 

 

 

 

the test modes will no longer appear in the mode list. Test weld modes typically require the machine out-

 

 

 

 

 

put to be connected to a grid load and cannot be used for welding.

 

 

 

 

 

 

 

 

 

 

P.100

View Diagnostics

 

 

 

 

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system.

 

 

 

 

 

Select "Yes" to access the diagnostic options in the menu. Additional parameters will

 

 

 

 

 

now appear in the setup menu (P.101, P.102, etc).

 

 

 

 

 

 

 

 

 

 

P.101

View Event Logs

 

 

 

 

 

 

Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate Control

 

 

 

 

 

Knob to select the desired event log to read. Press the Right Button again to enter the selected log.

 

 

 

 

 

Rotating the Control Knob will scroll through the event log, displaying the log index number, event code

 

 

 

 

 

and some other data. Press the Left Button to back out to select another log. Press the Left Button again

 

 

 

 

 

to exit this option.

 

 

 

 

 

 

 

 

 

 

P.102

View Fatal Logs

 

 

 

 

 

 

Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate Control Knob

 

 

 

 

 

to select the desired fatal log to read. Press the Right Button again to enter that log. Rotating the Control

 

 

 

 

 

Knob will scroll through the log, displaying the log index number and fatal code. Press the Left Button to

 

 

 

 

 

back out to select another log. Press the Left Button again to exit this option.

 

 

 

 

 

 

 

 

 

 

P.103

View Software Version Information

 

 

 

 

 

 

Used for viewing the software versions for each board in the system. Press the Right Button to

 

 

 

 

 

enter the option. Rotate Control Knob to select the desired board to read. Press the Right

 

 

 

 

 

Button again to read the firmware version. Press the Left Button to back out to select another

 

 

 

 

 

board. Rotate the Control Knob to select another board, or press the Left Button to exit this

 

 

 

 

 

option.

 

 

 

 

 

 

 

 

 

 

P.104

View Hardware Version Information

 

 

 

 

 

 

Used for viewing the hardware version for each board in the system. Press the right MSP

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

button again to read the hardware version. Press the left button to back out to select another

 

 

 

 

 

board. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

P.105

View Welding Software Information

 

 

 

 

 

 

Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld

 

 

 

 

 

Set version. Press the Left Button to back out and exit this option.

 

 

 

 

 

 

 

 

 

 

P.106

View Ethernet IP Address

 

 

 

 

 

 

Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to

 

 

 

 

 

read the IP Address. Press the Left Button to back out and exit this option. The IP address can-

 

 

 

 

 

not be changed using this option.

 

 

 

 

 

 

 

 

 

 

P.107

View Power Source Protocol

 

 

 

 

 

 

Used for viewing the type of power source the feeder is connected to. Press the Right Button to

 

 

 

 

 

identify the power source as either LincNet or ArcLink. Press the Left Button to back out and

 

 

 

 

 

exit this option.

 

 

 

 

 

 

 

 

 

POWER FEED™ 10M SINGLE WIRE FEEDER

Page 37
Image 37
Lincoln Electric IM915 Parameter Definition Show Test Modes, View Diagnostics, View Fatal Logs, View Ethernet IP Address