| USER DEFINED PARAMETERS |
|
|
|
| |
Parameter | Definition |
| |
|
|
| |
P.5 | Procedure Change Method |
|
This option selects how remote procedure selection (A/B) will be made. The selected procedure can be changed locally at the user interface by pressing the
*Use an external switch wired to the procedure select input.
*Quickly releasing and
*Using a
nism (pulling the trigger more than half way changes the procedure from A to B)
The possible values for this parameter are:
*External Switch = Procedure selection may only be performed at the memory panel or an external switch (e.g. K683).
*Quick Trigger = The selected procedure can be changed remotely by releasing and
-Select "GUN" on the memory panel.
-Start the weld by pulling the gun trigger. The system will weld with procedure A settings.
-While welding, quickly release then pull the gun trigger once. The system will switch to pro- cedure B settings. Repeat to switch back to procedure A settings. The procedure can be changed as many times as needed during the weld.
-Release the trigger to stop welding. The system will automatically return to procedure A settings.
*Integral TrigProc = When using a Magnum DS
P.6 | Stall Factor Adjustment |
| This option allows the adjustment of the stall factor in Push/Pull operation. The stall factor con- |
| trols the stall torque of the push motor when using a |
| set to not stall unless there is a large resistance to feeding wire. The stall factor can be reduced |
| to stall more easily and possibly prevent bird nesting. However, low stall factors can cause |
| motor stalling during normal welding conditions, which results in the wire burning back to the tip |
| or rapid tack welds. If you are experiencing bird nests, check for other feeding problems before |
| adjusting the stall factor. The default value for the stall factor is 75, with a range of 5 to 100. |