E-5

TROUbLESHOOTING

E-5

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

OUTPUT PRObLEMS

The feeder does power up - no dis-

1.

The Power Wave power source is

 

play, no cold feed.

 

OFF. Turn ON the Power Wave

 

 

 

power source.

 

 

2.

The circuit breaker for the wire

 

 

 

feeder on power source have

 

 

 

tripped. Reset the circuit break-

 

 

 

ers.

 

 

3.

The control cable may be loose

 

 

 

or damaged. Tighten, repair or

 

 

 

replace the control cable.

 

 

 

 

No shielding gas.

1. The gas supply is OFF or empty.

 

 

 

Verify the gas supply is ON and

 

 

 

flowing.

 

 

2.

The gas hose is cut or crushed.

 

 

 

Route the gas hose so it avoids

 

 

 

sharp corners and make sure

 

 

 

nothing is on top of it. Repair or

 

 

 

replace damaged hoses.

 

 

3.

Dirt or debris is in the solenoid.

 

 

 

Apply filtered shop at 80psi to the

 

 

 

solenoid to remove dirt.

 

 

4.

There is a loose solenoid connec-

 

 

 

tion. Remove the cover and

 

 

 

check that all connections are in

 

 

 

good condition.

 

 

5.

The solenoid has failed.

 

 

 

 

Gas solenoid not operating properly

1. Inlet gas pressure exceeding 80

 

or intermittent.

 

psi(5.5 bar). Verify that gas pres-

 

 

 

sure regulator is operating prop-

 

 

 

erly.

 

 

 

 

 

 

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.