OPERATION

b-25

 

 

 

MACHINE FUNCTIONALITY bY WELD PROCESS

CV GMAW/FCAW (NON-SYNERGIC)

Use the following tables to review how the machine functions (output controls, arc control, Start options and weld options) for the weld modes listed in the top table.

OUTPUT CONTROL KNObS, WELD MODE 5 & 6

OUTPUT CONTROL KNObS, WELD MODE 40

 

 

 

 

 

 

 

 

 

 

 

 

300

25.3

WFS AMPS

VOLTS TRIM

LESS

MORE

LESS

MORE

WFS

WFS

VOLTS

VOLTS

 

 

CV NON-SYNERGIC MODES

Material

PROCESS

WELD MODE

Steel

GMAW, CV

5

Steel

GMAW, POWER MODE

40

Steel

FCAW, CV

6

 

WAVEFORM CONTROL TECHNOLOGY

 

IR PORT

5

SETUP

 

 

STD CV MIG

 

WELD MODE

 

START OPTIONS

ARC CONTROL

 

END OPTIONS

 

SET

 

ARC CONTROL

 

 

 

 

 

 

 

EFFECT / RANGE

 

 

DESCRIPTION

 

 

(Soft)-10.0 to

 

 

Arc Force adjusts the short cir-

 

 

(Crisp)+10.0

 

 

cuit current for a soft arc, or for

 

 

 

 

 

a forceful, digging arc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

2.0

 

WFS

AMPS

VOLTS

TRIM

LESS

MORE

SHORTER

LONGER

WFS

WFS

ARC

ARC

START OPTIONS

The start Options available in these Non-Synergic CV weld modes, their adjustment range and function are as follows:

 

 

 

 

 

 

 

EFFECT / RANGE

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

Preflow Time

 

 

Adjusts the time the gas flows

 

0 to 25.0 seconds

 

 

after the trigger is pulled and

 

 

 

 

 

prior to feeding.

 

Run-In WFS:

 

 

Run-In sets the wire feed

 

Off, 30 to150 in/min.

 

 

speed from the time the trigger

 

 

 

 

 

is pulled until an arc is estab-

 

 

 

 

 

lished.

 

Start Procedure

 

 

The Start Procedure controls the

 

0 to 10 seconds

 

 

WFS and Volts for a specified time

 

 

 

 

 

at the beginning of the weld.

 

 

 

 

 

During the start time, the machine

 

 

 

 

 

will ramp up or down from the

 

 

 

 

 

Start Procedure to the preset

 

 

 

 

 

Welding Procedure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

END OPTIONS

 

 

 

 

 

 

 

 

 

EFFECT / RANGE

 

 

DESCRIPTION

 

 

 

 

 

 

Spot Timer:

 

 

 

Adjusts the time welding will continue

 

 

0 to 120.0 Seconds

 

 

even if tigger is still pulled. This option

 

 

 

 

 

has no effect in 4-Step Trigger Mode.

 

Postflow Time

 

 

 

Adjusts the time that shielding gas

 

 

 

 

 

 

 

0 to 25.0 seconds

 

 

flows after the welding output turns off.

 

Crater Procedure

 

 

 

Crater Procedure controls the WFS

 

 

(0 TO 10.0 SECONDS)

 

 

and Volts for a specified time at the

 

 

 

 

 

end of the weld after the trigger is

 

 

 

 

 

released. During the Crater time, the

 

 

 

 

 

machine will ramp up or down from the

 

 

 

 

 

Weld Procedure to the Crater

 

 

 

 

 

Procedure.

 

Burnback:

 

 

 

The burnback time is the amount of

 

 

0 to .25 Seconds

 

 

time that the weld output continues

 

 

 

 

 

after the wire stops feeding. It prevents

 

 

 

 

 

the wire from sticking in the puddle and

 

 

 

 

 

prepares the end of the wire for the

 

 

 

 

 

next arc start.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 