OPERATION | ||
|
|
|
WELD MODE SEARCHING
The Weld Mode Search feature allows the selection of a welding mode based on certain criteria (wire size, process type, etc.).
SEARCHING FOR A WELD MODE
To search for a mode, turn the control knob until “Weld Mode Search” is displayed. This will appear in between the highest and the lowest weld mode num- bers.
Once “Weld Mode Search” is displayed, pressing the right pushbutton labeled “Begin” will start the search process.
During the search process, pressing the right pushbut- ton typically acts as a “next” button and the left push- button typically acts as a “back” button.
Rotate the control knob then press the right pushbut- ton to select relevant welding details such as welding process, wire type, wire size, etc.
When the final selection is made, the PF10M™ will automatically change to the weld mode found by the Weld Mode Search process.
Earlier products may not have this feature. To acti- vate this feature, a software update may be needed from www.powerwavesoftware.com
USER MEMORIES
Recall a memory with memory buttons
To recall a user memory, press one of the six user memory buttons. The memory is recalled when the button is released. Do not hold the button for more than two seconds when recalling a user memory.
Recall a memory with the gun trigger
If desired, memories 2 through 6 can be recalled with the gun trigger. For example, to recall memory 3, quickly pull and release the gun trigger 3 times without welding.
Note: the Power Feed™ 10M Single Wire Feeder is factory set with this feature disabled. Use the SETUP menu and change P.4 to enable memory recall with the gun trigger.
Save a memory with memory buttons
To save a memory, press and hold the desired memo- ry button for two seconds. When the button is initially pressed, the corresponding LED will illuminate. After two seconds, the LED will turn off. Do not hold the button for more than 5 seconds when saving a user memory.
Note that memories may be locked in the Setup menu to prevent accidental overwrite of the memories. If an attempt is made to save a memory when memory sav- ing is locked, the message "Memory save is Disabled!" will appear briefly in the MSP4 display.
RECALL |
|
| SAVE |
|
PRESS 1 |
|
| PRESS 2 |
|
SECOND |
| SECONDS |
| |
|
| M | MEMORY | M |
PROCEDURE |
|
|
|
|
A GUN B | 1 |
| 2 | 3 |
|
|
HOLD 2 SECONDS TO SAVE
4 5 6